SECTION 5
Pronar N262 N262/1
5.21
Draining water from air tank:
•
after each week of use.
5.3.5 CLEAN DRAIN VALVE
DANGER
Before dismantling drain valve release air from tank.
Required service actions
Reduce pressure in air tank.
Reduction of pressure in tank is achieved by tilting the drain valve
stem.
Unscrew valve.
Clean valve, purge with compressed air.
Change copper seal.
Screw in valve, fill air tank, and check tank tightness.
Cleaning valve:
•
every 12 months (before winter period).
5.3.6 CLEANING AND MAINTAINING PNEUMATIC LINE CONNECTIONS AND
PNEUMATIC SOCKETS
DANGER
Unreliable and dirty manure spreader connections may cause unreliability and faulty
functioning of braking system.
In event of damage to cover or seal, change these elements for new reliable elements.
Contact of pneumatic connector seals with oils, grease, petrol etc. may cause damage and
accelerate ageing process.