Section 22: HEATING AND AIR CONDITIONING
PA1593
26
compressor and other components causing a
malfunction and eventual failure of the system.
Uncontrolled moisture in the system can result
in very expensive multiple component
replacements if not corrected at an early stage.
The moisture indicator permits an early
detection of moisture in the system and when
corrected by a desiccant charge, system
contamination is greatly minimized.
7.7 LIQUID REFRIGERANT SOLENOID
VALVE
The flow of liquid refrigerant to the driver’s and
main evaporators is controlled by a normally-
closed solenoid valve. The driver’s liquid
solenoid valve is located on the ceiling of the
spare wheel and tire compartment and is
accessible through the reclining bumper.
FIGURE 31: DRIVER'S EVAPORATOR LIQUID SOLENOID
VALVE
22324
7.7.1 Manual
Bypass
This type of solenoid valve is equipped with a
manual operating stem. The 3/16" square stem
located on the bonnet is exposed when the seal
cap is removed. To manually open valve, turn
stem ½ turn counterclockwise. To manually
close valve, turn stem clockwise until tight
against seat. Manual stem must be in closed
position for automatic electric operation.
7.7.2 Coil
Replacement
1. Disconnect connector from the coil
connector.
2. Take out the retaining screw at the top of
the coil housing. The entire coil assembly
can then be lifted off the enclosing tube.
3. Place the new coil and yoke assembly on
the enclosing tube. Lay data identification
plate in place.
4. Insert the coil retaining screw, rotate
housing to proper position and tighten screw
securely.
5. Connect connector from coil connector.
7.7.3 Valve
Disassembly
1. Remove the coil as stated previously.
2. Pump down the system as stated earlier in
this section.
3. Remove the four socket head screws which
hold the body and bonnet together (Fig. 32).
4. Carefully lift off the bonnet assembly (upper
part of the valve) so that plunger will not fall
out. The diaphragm can now be lifted out.
NOTE
The above procedure must be followed before
brazing solder-type bodies into the line.
CAUTION
Be careful not to damage the machined faces
while the valve is apart.
7.7.4 Valve
Reassembly
1. Place the diaphragm in the body with the
pilot port extension up.
2. Hold the plunger with the synthetic seat
against the pilot port.
3. Make sure the bonnet O-rings are in place.
Lower the bonnet assembly over the
plunger, making sure that the locating
sleeve in the bonnet enters the mating hole
in the body.
4. Insert the four socket head screws and
tighten evenly.
Содержание X3-45 2016
Страница 4: ......
Страница 16: ...Section 00 GENERAL INFORMATION PA1593 12 FIGURE 12 METRIC US STANDARD CONVERSION TABLE 00005...
Страница 17: ...Section 00 GENERAL INFORMATION 13 PA1593 FIGURE 13 CONVERSION CHART 00006...
Страница 18: ......
Страница 26: ......
Страница 58: ......
Страница 72: ...Section 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 14 7 TORQUE SPECIFICATIONS...
Страница 73: ...SECTION 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 15...
Страница 74: ...Section 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 16...
Страница 76: ......
Страница 96: ......
Страница 134: ......
Страница 176: ...SECTION 06B ELECTRICAL 38 overcurrent working Circuit 306 shorted to ground...
Страница 180: ......
Страница 202: ......
Страница 205: ...Section 09 PROPELLER SHAFT PA1593 3 FIGURE 1 PROPELLER SHAFT ASSEMBLY 09002...
Страница 256: ......
Страница 268: ......
Страница 295: ...SECTION 16 SUSPENSION PA1593 9 2 5 TORQUE SPECIFICATIONS...
Страница 296: ...Section 16 SUSPENSION PA1593 10...
Страница 297: ...Section 16 SUSPENSION PA1593 11...
Страница 314: ......
Страница 364: ...Section 18 BODY PA1593 50 6 8 BODY PANEL AND WINDOW SPACING FIGURE 45 BODY PANEL AND WINDOW SPACING TYPICAL 18631...
Страница 380: ......
Страница 388: ......
Страница 413: ...Section 22 HEATING AND AIR CONDITIONING PA1593 15 FIGURE 18 REFRIGERANT CIRCUIT CENTRAL SYSTEM...
Страница 433: ...Section 22 HEATING AND AIR CONDITIONING PA1593 35 FIGURE 36 CENTRAL HEATING SYSTEM COMPONENTS...