SECTION 06B: ELECTRICAL
16
MID 188 PSID # 130 Flasher LH (A45 J1:9)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage present on
input A45 J1:9 but
output not active
LH flasher not
working
A45 module failure
Connector Foot:B corroded
Circuit 21 shorted to battery
FMI 4
Shorted Low
Input A45 J1:9
shorted to ground
LH flasher
always ON
A45 module failure
Foot switch Sw138 failure
Connector Foot:B corroded
Circuit 21 shorted to ground
MID 188 PSID # 37 Foot trap (A45 J1:2)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage present on
output A45 J1:2 but
output not active
Foot damper
Mo4 always
ON
A45 module failure
Foot Damper Mo4 failure
Connector C72 corroded
Circuit 65A shorted to battery
FMI 4
Shorted Low
Output A45 J1:2
shorted to ground
Foot damper
Mo4 not
working
A45 module failure
Foot Damper Mo4 failure
Connector C72 corroded
Circuit 65A shorted to ground
FMI 6
Current
above normal
Output A45 J1:2
internal software fuse
active for overcurrent
Foot damper
Mo4 not
working
A45 module failure
Connector C72 corroded
Circuit 65A shorted to ground
MID 188 PSID # 137 FR Clearance lights (A44 J1:8)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage present on
output A44 J1:8 but
output not active
Front Clearance
Lights always ON
A44 module failure
Connector C45 corroded
Circuit 63A shorted to battery
FMI 4
Shorted Low
Output A44 J1:8
shorted to ground
Front Clearance
Lights not
working
A44 module failure
Connector C45 corroded
Circuit 63A shorted to ground
FMI 5
Open Circuit
A44 module does
not detect Front
Clearance Lights
Front Clearance
Lights not
working
A44 module failure
L16 open circuit
Circuit 63A open
FMI 6
Current
above normal
Output A44 J1:8
internal software
fuse active for
overcurrent
Front Clearance
Lights not
working
A44 module failure
Connector C45 corroded
Circuit 63A shorted to ground
MID 188 PSID # 128 Fr Flsh-Mkr LH (A45 J1:3)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage present on
output A45 J1:3 but
output not active
Front LH
flasher and
marker lights
always ON
A45 module failure
Connector C4 corroded
Connector C242 corroded
Circuit 21A shorted to battery
Содержание X3-45 2016
Страница 4: ......
Страница 16: ...Section 00 GENERAL INFORMATION PA1593 12 FIGURE 12 METRIC US STANDARD CONVERSION TABLE 00005...
Страница 17: ...Section 00 GENERAL INFORMATION 13 PA1593 FIGURE 13 CONVERSION CHART 00006...
Страница 18: ......
Страница 26: ......
Страница 58: ......
Страница 72: ...Section 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 14 7 TORQUE SPECIFICATIONS...
Страница 73: ...SECTION 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 15...
Страница 74: ...Section 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 16...
Страница 76: ......
Страница 96: ......
Страница 134: ......
Страница 176: ...SECTION 06B ELECTRICAL 38 overcurrent working Circuit 306 shorted to ground...
Страница 180: ......
Страница 202: ......
Страница 205: ...Section 09 PROPELLER SHAFT PA1593 3 FIGURE 1 PROPELLER SHAFT ASSEMBLY 09002...
Страница 256: ......
Страница 268: ......
Страница 295: ...SECTION 16 SUSPENSION PA1593 9 2 5 TORQUE SPECIFICATIONS...
Страница 296: ...Section 16 SUSPENSION PA1593 10...
Страница 297: ...Section 16 SUSPENSION PA1593 11...
Страница 314: ......
Страница 364: ...Section 18 BODY PA1593 50 6 8 BODY PANEL AND WINDOW SPACING FIGURE 45 BODY PANEL AND WINDOW SPACING TYPICAL 18631...
Страница 380: ......
Страница 388: ......
Страница 413: ...Section 22 HEATING AND AIR CONDITIONING PA1593 15 FIGURE 18 REFRIGERANT CIRCUIT CENTRAL SYSTEM...
Страница 433: ...Section 22 HEATING AND AIR CONDITIONING PA1593 35 FIGURE 36 CENTRAL HEATING SYSTEM COMPONENTS...