SECTION 06C: ELECTRICAL
1
MULTIPLEX MODULE “NO RESPONSE” TROUBLESHOOTING LIST
FRONT JUNCTION BOX MODULES
MID 188 PSID # 216 A41 MODULE NO RESPONSE
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 2
Data Error
A41 Module not
responding on CAN
network
A41 module all
inputs and outputs
not responding
CAN network open
Address Jumper open circuit
Fuse F110 defective
Relay R18 defective
MID 188 PSID # 217 A42 MODULE NO RESPONSE
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 2
Data Error
A42 Module not
responding on CAN
network
A42 module all
inputs and outputs
not responding
CAN network open
Address Jumper open circuit
Fuse F12 or F13 defective
MID 188 PSID # 218 A43 MODULE NO RESPONSE
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 2
Data Error
A43 Module not
responding on CAN
network
A43 module all
inputs and outputs
not responding
CAN network open
Address Jumper open circuit
Fuse F12 or F13 defective
MID 188 PSID # 219 A44 MODULE NO RESPONSE
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 2
Data Error
A44 Module not
responding on CAN
network
A44 module all
inputs and outputs
not responding
CAN network open
Address Jumper open circuit
Fuse F21 defective
MID 188 PSID # 220 A45 MODULE NO RESPONSE
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 2
Data Error
A45 Module not
responding on CAN
network
A45 module all
inputs and outputs
not responding
CAN network open
Address Jumper open circuit
Fuse F33 or F34 defective
Relay R19 defective
MID 188 PSID # 221 A46 MODULE NO RESPONSE
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 2
Data Error
A46 Module not
responding on CAN
network
A46 module all
inputs and outputs
not responding
CAN network open
Address Jumper open circuit
Fuse F12 or F13 defective
Содержание X3-45 2016
Страница 4: ......
Страница 16: ...Section 00 GENERAL INFORMATION PA1593 12 FIGURE 12 METRIC US STANDARD CONVERSION TABLE 00005...
Страница 17: ...Section 00 GENERAL INFORMATION 13 PA1593 FIGURE 13 CONVERSION CHART 00006...
Страница 18: ......
Страница 26: ......
Страница 58: ......
Страница 72: ...Section 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 14 7 TORQUE SPECIFICATIONS...
Страница 73: ...SECTION 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 15...
Страница 74: ...Section 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 16...
Страница 76: ......
Страница 96: ......
Страница 134: ......
Страница 176: ...SECTION 06B ELECTRICAL 38 overcurrent working Circuit 306 shorted to ground...
Страница 180: ......
Страница 202: ......
Страница 205: ...Section 09 PROPELLER SHAFT PA1593 3 FIGURE 1 PROPELLER SHAFT ASSEMBLY 09002...
Страница 256: ......
Страница 268: ......
Страница 295: ...SECTION 16 SUSPENSION PA1593 9 2 5 TORQUE SPECIFICATIONS...
Страница 296: ...Section 16 SUSPENSION PA1593 10...
Страница 297: ...Section 16 SUSPENSION PA1593 11...
Страница 314: ......
Страница 364: ...Section 18 BODY PA1593 50 6 8 BODY PANEL AND WINDOW SPACING FIGURE 45 BODY PANEL AND WINDOW SPACING TYPICAL 18631...
Страница 380: ......
Страница 388: ......
Страница 413: ...Section 22 HEATING AND AIR CONDITIONING PA1593 15 FIGURE 18 REFRIGERANT CIRCUIT CENTRAL SYSTEM...
Страница 433: ...Section 22 HEATING AND AIR CONDITIONING PA1593 35 FIGURE 36 CENTRAL HEATING SYSTEM COMPONENTS...