Section 22: HEATING AND AIR CONDITIONING
PA1593
16
WARNING
Always wear safety goggles when opening
refrigerant lines.
5. In the event that any line is opened to the
atmosphere, it should be immediately
capped to prevent entrance of moisture and
dirt.
6. The use of the proper wrenches when
making connections on O-ring fittings is
important. The use of improper wrenches
may damage the connection. The opposing
fitting should always be backed up with a
wrench to prevent distortion of connection
lines or components. When connecting the
flexible hose connections, it is important
that the swaged fitting and the flare nut, as
well as the coupling to which it is attached,
be held at the same time using three
different wrenches to prevent turning the
fitting and damaging the ground seat.
7. The O-rings and seats must be in perfect
condition. The slightest burr or piece of dirt
may cause a leak.
8. O-rings should be coated with refrigeration
oil and installed on the line before the line is
inserted into the fitting to prevent damaging
the O-ring. If leaks are encountered at the
couplings or connectors, no attempt should
be made to correct the leaks by tightening
the connections beyond the recommended
torque. The O-rings are designed to seal at
the specified torque and overtightening the
connection does not result in a satisfactory
and permanently sealed connection. The
connection must be disassembled and the
cause of the leak (damaged O-ring,
defective lines, etc.) corrected. Use new
O-ring.
6.3 PUMPING
DOWN
This procedure is intended to reduce refrigerant
loss, by isolating it in the compressor and the
receiver tank, as well as in their connecting line,
in order to carry out repairs on other sections of
the air conditioning system (lines and
components).
NOTE
Before attempting any repair between
compressor and receiver tank, use a recovery
unit to remove refrigerant from the system.
WARNING
To prevent any injury, when air conditioning
system must be opened, refer to previous
paragraph “PRECAUTIONS IN HANDLING
REFRIGERANT”.
CAUTION
The filter dryer must be changed each time a
line in the system is opened.
Procedure
1. Energize passengers ‘section liquid solenoid
valve.
2. Run the system for 10 minutes, shut it OFF,
then close the receiver tank outlet valve by
turning it clockwise, backseat the suction
service valve on the compressor, install an
appropriate pressure gauge set, and turn
the valve forward ¼ turn to enable a visual
check of the suction pressure.
3. Disconnect the
“Low Pressure Switch”
connector (mounted near the A/C
compressor, and install a jumper wire.
NOTE
This jumper wire will allow the clutch to remain
engaged after pressure drops below 15 psi
(103,5 kPa).
4. Start the engine, press the
“Driver’s
ON/OFF”
switch then adjust (lower)
temperature control
to maximum
A/C.
5. Run the compressor until pressure reaches
1-2 psi (7-14 kPa).
NOTE
During this operation, care must be taken not
to fill the receiver tank over the upper sight
glass. If so, stop process immediately. Always
allow refrigerant piping and units to warm up
to the ambient air temperature before opening
system or sweating will take place inside the
lines.
6. Stop engine, and close compressor outlet
valve by turning it clockwise until valve is
properly seated.
Содержание X3-45 2016
Страница 4: ......
Страница 16: ...Section 00 GENERAL INFORMATION PA1593 12 FIGURE 12 METRIC US STANDARD CONVERSION TABLE 00005...
Страница 17: ...Section 00 GENERAL INFORMATION 13 PA1593 FIGURE 13 CONVERSION CHART 00006...
Страница 18: ......
Страница 26: ......
Страница 58: ......
Страница 72: ...Section 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 14 7 TORQUE SPECIFICATIONS...
Страница 73: ...SECTION 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 15...
Страница 74: ...Section 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 16...
Страница 76: ......
Страница 96: ......
Страница 134: ......
Страница 176: ...SECTION 06B ELECTRICAL 38 overcurrent working Circuit 306 shorted to ground...
Страница 180: ......
Страница 202: ......
Страница 205: ...Section 09 PROPELLER SHAFT PA1593 3 FIGURE 1 PROPELLER SHAFT ASSEMBLY 09002...
Страница 256: ......
Страница 268: ......
Страница 295: ...SECTION 16 SUSPENSION PA1593 9 2 5 TORQUE SPECIFICATIONS...
Страница 296: ...Section 16 SUSPENSION PA1593 10...
Страница 297: ...Section 16 SUSPENSION PA1593 11...
Страница 314: ......
Страница 364: ...Section 18 BODY PA1593 50 6 8 BODY PANEL AND WINDOW SPACING FIGURE 45 BODY PANEL AND WINDOW SPACING TYPICAL 18631...
Страница 380: ......
Страница 388: ......
Страница 413: ...Section 22 HEATING AND AIR CONDITIONING PA1593 15 FIGURE 18 REFRIGERANT CIRCUIT CENTRAL SYSTEM...
Страница 433: ...Section 22 HEATING AND AIR CONDITIONING PA1593 35 FIGURE 36 CENTRAL HEATING SYSTEM COMPONENTS...