SECTION 06B: ELECTRICAL
37
or position
Circuit 85B shorted to ground
FMI 5
Open Circuit
A36 module does
not detect 24v Fr
WUp relay R18,
12v Fr WUp relay
R19, 12v Rr WUp
relay R17 or 12v
Rr Engine ECU
relay R34
Various systems
not working
depending on relay
or position
A36 module failure
Various WUp Relays R17,
R18, R19, R34 open circuit
Circuit 85B open
FMI 6
Current
above normal
Output A36 JA:15
internal software
fuse active for
overcurrent
Various systems
not working
depending on relay
or position
A36 module failure
Connector C2 or C21 corroded
Circuit 85B shorted to ground
MID 188 PSID # 176 WCL Pump Rly (A53 J1:5)
Type of
fault:
FMI
Description:
Fault Condition: Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage present
on output A53
J1:5 but output
not active
WCL Pump
Assy L207 can
be operated is
sensor Se100
is active
A53 module failure
WCL Door open Relay R47 failure
Connector C27, C31 or C29
corroded
Circuit 304 shorted to battery
FMI 4
Shorted Low
Output A53 J1:5
shorted to ground
WCL Pump
Assy L207 not
working
A53 module failure
WCL Door open Relay R47 failure
Connector C27, C31 or C29
corroded
Circuit 304 shorted to ground
FMI 6
Current
above normal
Output A53 J1:5
internal software
fuse active for
overcurrent
WCL Pump
Assy L207 not
working
A53 module failure
Connector C27, C31 or C29
corroded
Circuit 304 shorted to ground
MID 188 SID # 24 WCLDorSig to USonic (A53 J1:7)
Type of
fault:
FMI
Description:
Fault Condition: Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage present
on output A53
J1:7 but output
not active
WCL Door
open Relay
R47 always ON
A53 module failure
WCL Door open Relay R47 failure
Connector C27, C31 or C29
corroded
Circuit 306 shorted to battery
FMI 4
Shorted Low
Output A53 J1:7
shorted to ground
WCL Door
open Relay
R47 not
working
A53 module failure
WCL Door open Relay R47 failure
Connector C27, C31 or C29
corroded
Circuit 306 shorted to ground
FMI 5
Open Circuit
A53 module does
not detect WCL
Door open Relay
R47
WCL Door
open Relay
R47 not
working
A53 module failure
WCL Door open Relay R47 failure
Circuit 306 open
FMI 6
Current
above normal
Output A53 J1:7
internal software
fuse active for
WCL Door
open Relay
R47 not
A53 module failure
Connector C27, C31 or C29
corroded
Содержание X3-45 2016
Страница 4: ......
Страница 16: ...Section 00 GENERAL INFORMATION PA1593 12 FIGURE 12 METRIC US STANDARD CONVERSION TABLE 00005...
Страница 17: ...Section 00 GENERAL INFORMATION 13 PA1593 FIGURE 13 CONVERSION CHART 00006...
Страница 18: ......
Страница 26: ......
Страница 58: ......
Страница 72: ...Section 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 14 7 TORQUE SPECIFICATIONS...
Страница 73: ...SECTION 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 15...
Страница 74: ...Section 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 16...
Страница 76: ......
Страница 96: ......
Страница 134: ......
Страница 176: ...SECTION 06B ELECTRICAL 38 overcurrent working Circuit 306 shorted to ground...
Страница 180: ......
Страница 202: ......
Страница 205: ...Section 09 PROPELLER SHAFT PA1593 3 FIGURE 1 PROPELLER SHAFT ASSEMBLY 09002...
Страница 256: ......
Страница 268: ......
Страница 295: ...SECTION 16 SUSPENSION PA1593 9 2 5 TORQUE SPECIFICATIONS...
Страница 296: ...Section 16 SUSPENSION PA1593 10...
Страница 297: ...Section 16 SUSPENSION PA1593 11...
Страница 314: ......
Страница 364: ...Section 18 BODY PA1593 50 6 8 BODY PANEL AND WINDOW SPACING FIGURE 45 BODY PANEL AND WINDOW SPACING TYPICAL 18631...
Страница 380: ......
Страница 388: ......
Страница 413: ...Section 22 HEATING AND AIR CONDITIONING PA1593 15 FIGURE 18 REFRIGERANT CIRCUIT CENTRAL SYSTEM...
Страница 433: ...Section 22 HEATING AND AIR CONDITIONING PA1593 35 FIGURE 36 CENTRAL HEATING SYSTEM COMPONENTS...