background image

24

5

Resources

Monitor StationV2

常使用过程中,适用性的保证,在时间上都限于本有限保证的长度。有些州不允许
限制隐含保证的持续时间,因此上述限制可能不适用于你。在任何情况下,

PreSonus

都不对违反任何明示或默示保证而导致的意外、后果性或其他损害负责,包括财产损害、
基于不便或产品使用损失的损害,以及在法律允许的范围内,人身伤害的损害。有些州
不允许排除对附带或间接损害的限制,因此上述限制或排除可能不适用于你。本保证给
予你特定的法律权利,你也可能有其他权利,这些权利因州而异。本保证只适用于在美
国境内销售和使用的产品。关于所有其他国家的保修信息,请参考你当地的经销商。

PreSonus Audio Electronics, Inc.

公司

18011 Grand Bay Court
Baton Rouge, LA 70809 USA
1-225-216-7887
www.presonus.com (

官网网址

)

Содержание TubePre V2

Страница 1: ...Monitor StationV2 Desktop Studio Control Center Owner s Manual www presonus com English...

Страница 2: ...io Sources 5 2 1 5 Connecting Speakers to the Monitor Station V2 V2 6 2 1 6 CalibratingYourSpeakerLevels 7 2 1 7 CalibratetheTalkbackMicrophone 10 2 1 8 Connect the CueOutputs 10 2 1 9 Connect the Mai...

Страница 3: ...at 1 225 216 7887 with any questions or comments you have about your Monitor Station V2 PreSonus Audio Electronics is committed to constant product improvement and we highly value your suggestions We...

Страница 4: ...m Mono Level controls The individual Source and Level controls for the Monitor Station V2 s four amplified headphone outputs allow you to individually configure and adjust what s heard in each perform...

Страница 5: ...In addition to this manual the Monitor Station V2 package contains the following Monitor Station V2 Monitor Station V2 Studio Control Center Monitor Station V2 external power supply PreSonus Health Sa...

Страница 6: ...ountry in which you re using it PreSonus supports only the power supply shipped with your Monitor Station V2 If the power supply doesn t meet your local requirements or if you wish to purchase an addi...

Страница 7: ...el Cue Output Zero 2 Connect your primary audio source computer audio interface mixer or other stereo source to the balanced TRS ST1 L R inputs on the back of your Monitor Station V2 3 Ifyouhaveasecon...

Страница 8: ...described in Section 4 1 3 RCA 1 8 4 1 3 S PDIF 2 1 3 Calibratingthe MonitorStationV2 sLED Meter Monitor Station V2 LED By default the Monitor Station V2 s LED meters are calibrated so that the red 0...

Страница 9: ...ne back or by generating it from an internal oscillator You can find and download free test tone audio files from the internet if necessary 1kHz When using a test tone make sure there s no processing...

Страница 10: ...date the device Adjust the meter s range as described in Section 2 1 3 then repeat steps 2 5 in this section Realityvs UnityGain Unity Gain 0 Unity Gain Monitor Station V2 0 VU LED Monitor Station V2...

Страница 11: ...tablishes a comfortable maximum level for your studio environment A healthy monitoring level for a small control room environment would be 78 dB For a large environment 85 dB makes more sense You can...

Страница 12: ...tal to analog converters are configured so that 0 dBFS equals a certain amount of voltage For example a 0 dBFS tone playing at Unity Gain from an AudioBox 1818VSL or FireStudio Project audio interface...

Страница 13: ...aker sets after calibration After all that s why monitoring with multiple systems helps ensure your mixes and recordings sound good wherever they re played Calibrating Your Primary Speakers This speak...

Страница 14: ...Main Source Speaker A Speaker Select 5 In your DAW or on your noise generator pan the pink noise all the way to the left since we ll start by calibrating the left speaker DAW 6 Make sure your pink no...

Страница 15: ...your calibrations by playing audio through Speaker A only and then making no other adjustments toggling Speaker A off and Speaker B on You may hear a slight tonal variance due to the different acoust...

Страница 16: ...s Cue 3 Play some typical audio such as a song on your phone or an existing project and select that audio source as your only input to the Cue bus as described in Section 4 1 2 Cue 4 1 2 4 Put on the...

Страница 17: ...R Line 4 1 2 Cue Source Cue Source 4 1 2 Here s how to calibrate a headphone amplifier 1 Zero the Main Level and Cue Output knobs by turning them fully counterclockwise Main Level Cue Output 2 Connect...

Страница 18: ...ey carry is determined by the Main Source described in Section 3 1 4 and their output level is equal to the original input source level Main L R Line Outputs Monitor Station V2 thru Main Source 3 1 4...

Страница 19: ...tput Two monitoring systems for auditioning mixes are connected along with a subwoofer The Cue L R outputs are connected to a headphone distributing amplifier and the Main L R outputs are feeding a di...

Страница 20: ...m a factory reset as described in Section 2 3 4 Monitor Station V2 Monitor Station V2 2 3 4 2 3 1 SpeakerSelectModes Hold down Speaker Select To select So that Speaker A Combo mode all of the Speaker...

Страница 21: ...our monitoring devices have a maximum input of 10 dBu or if none of your input devices have a maximum or nominal output level greater than 10 dBu AUX 18 dBu mode the LED meter references 0 VU to 18 dB...

Страница 22: ...evice with an S PDIF output to this RCA digital input The Monitor Station V2 supports sample rates of 44 1 48 88 2 and 96 kHz S PDIF RCA Monitor Station V2 44 1 48 88 2 96kHz L R Aux Connect the left...

Страница 23: ...ks to the inputs of a stereo device TRS Cue L R Line Outputs The Cue L R outputs derive their signal from the Cue Source selection and their level is controlled by the Cue Output knob Connect the bala...

Страница 24: ...e gain level of the Talkback microphone preamplifier from 15 to 55 dB Talkback Level Knob 15 55dB Talk Button The Talk button engages and disengages the Talkback microphone preamplifier The Main and C...

Страница 25: ...or S PDIF audio input source according to the setting of the Aux SPDIF switch described in Section 4 1 3 Aux 4 1 3 Aux SPDIF Aux S PDIF When shipped from the factory the Monitor Station V2 s Cue Sourc...

Страница 26: ...Outputs and any headphone amplifiers whose Source switch is set to its Main position up Press ST1 to select the audio input source connected to the rear panel ST1 L R Inputs Press ST2 to select the a...

Страница 27: ...lect modes see Section 2 3 Speaker Selec Toggle Speaker Select 2 3 4 1 6 Main LevelControls This area contains your primary listening controls for the Monitor Station V2 Monitor Station V2 Main LevelC...

Страница 28: ...er systems Note that the Mute button has no effect on the Main L R Line Outputs MuteButton Mute Monitor Station V2 Mute L R Dim Button Press and light the Dim button to quickly reduce the outputs to y...

Страница 29: ...u Auxiliary Inputs Type RCA ActiveUnbalanced InputImpedance 47 5k S NRatio 1kHz 10dBu UnityGain 100dB THD N unwtd 1kHz 0dBuOutput UnityGain 0 005 FrequencyResponse 0 5dB 10Hz to50kHz GainRange 60dB to...

Страница 30: ...eStereo MaximumOutput 60 load 150mW channel FrequencyResponse 1 0dB 10Hzto50kHz Power PowerSupplyType ExternalDCTransformer InternalLine InputConnectorType Barrel 5 5mmoutsidediameter 2 1mminsidediame...

Страница 31: ...d Dim buttons and then slowly turn up the Main output level knob Move your speakers to a different output to verify its original outputs are functioning properly Connect the input source directly to y...

Страница 32: ...om Online technical support is available at http www presonus com support Contact Technical Support http www presonus com support Contact Technical Support Technical support is available via email at...

Страница 33: ...time without prior notice This warranty does not cover claims for damage due to abuse neglect alteration or attempted repair by unauthorized personnel and is limited to failures arising during normal...

Страница 34: ...24 5 Resources Monitor StationV2 PreSonus PreSonus Audio Electronics Inc 18011 Grand Bay Court Baton Rouge LA 70809 USA 1 225 216 7887 www presonus com...

Страница 35: ...eat 1 Tbsp of the oil on medium high heat and brown the andouille until it is cooked through Set aside sausage forlater 1 3 In the same saucepan add and heat remaining oil Slowly add flour 1 2 Tbsp at...

Страница 36: ...igiMax Eris FireStudio Nimbit PreSonus QMix Riff to Release Sceptre StudioLive and XMAX are trademarks or registered trademarks of PreSonus Audio Electronics Inc Capture Impact Mixverb Presence RedLig...

Страница 37: ...Monitor StationV2 Desktop Studio Control Center Owner s Manual 18011 Grand Bay Ct Baton Rouge Louisiana 70809 USA 1 225 216 7887 www presonus com Part 820 MS20029 B...

Отзывы: