OPERATION AND MAINTENANCE MANUAL
Rev. 03-21
GENERAL SAFETY RULES
Whatever the nature of the maintenance, it must only be carried out by specialised technical
personnel.
In the event of failure or maintenance of the electrical system, before proceeding
with any check, the power supply to the panel must be disconnected by placing
the main power switch in the open position (O). Check the absence of voltage with
a Tester before any operation. Every element of the electrical panel, in the event
that it is faulty, must be replaced exclusively with original parts.
If the intervention involves parts outside the panel, perform the following steps:
❑
Permanently and safely disconnect the power supply to the panel in one of the
following ways:
1)
Turn the main switch of the NECTOR to OFF to lock it in this position using
a mechanical lock (Pego
ACC5ST3801
accessory).
2)
Disconnect the power supply upstream of our panel permanently by
padlocking it to OFF.
❑
Place signs to indicate the machine being serviced.
Before proceeding with maintenance operations, perform the following safety
requirements:
❑
The electrical panel must be powerless.
❑
Prevent the presence of unauthorised personnel in the intervention area.
❑
Place appropriate signs to indicate "Machine in Maintenance".
❑
Wear suitable work clothing (overalls, gloves, shoes, headgear) and free of
loose appendages.
❑
Remove any objects that may become entangled in protruding parts of the
panel.
❑
Have available accident prevention means and tools suitable for the operation.
❑
The tools must be well cleaned and degreased.
❑
Have the necessary technical documentation available to perform the
maintenance work (wiring diagrams, tables, drawings, etc.).
At the end of the maintenance operations, remove all residual materials and
thoroughly clean the panel.
It is absolutely forbidden to house additional parts inside the electrical panel.
MAINTENANCE
8.1
Содержание NECTOR
Страница 2: ...NECTOR Page 2 OPERATION AND MAINTENANCE MANUAL Rev 03 21...
Страница 61: ...NECTOR Page 61 OPERATION AND MAINTENANCE MANUAL Rev 03 21 NECTOR200 CONNECTION DIAGRAM INPUTS OUTPUTS A 2...
Страница 62: ...NECTOR Page 62 OPERATION AND MAINTENANCE MANUAL Rev 03 21...
Страница 63: ...NECTOR Page 63 OPERATION AND MAINTENANCE MANUAL Rev 03 21...