5.5 12-ZONE SySTEM
5.5.1 CONNECTION
Example.of.connection.of.two.PA8506-V.units.so.as.to.configure.a.system.with.a.total.of.up.to.12.zones,.using.the.REMOTE.LINK..
It.is.also.possible.to.add.to.each.PA8506-V.unit.its.own.optional.AW.5624.amplifier.for.increasing.the.output.power.up.to.a.total.of.980.W..As.
far.as.concerns.sizing.and.the.settings.for.each.PA8506-V.unit,.reference.should.be.made.to.points.5.1.1.and.5.1.2.
Basically,.the.two.units.function.as.two.separate.systems.covering.six.zones.each,.but.which.share.the.generic.signalling.referred.to.their.
operating.conditions.for.the.“Failure”,.“Alarm”.and.”Disabled”.status.affecting.the.system.as.a.whole.
With.the.addition.of.a.PMB132-V.or.PMB132/12-V.remote.microphone.station,.connected.to.an.EMERGENCY.UNIT.socket.and.set.in.the.GLOBAL.
mode,.it.is.possible.to.send.out.alerts.and.emergency.messages.throughout.the.12.zones..For.the.settings.see.point.8.6.4
It.is.also.possible.to.broadcast.announcements.selectively.to.the.12.zones.via.the.PMB112-G.PAGING.UNITS.
After. making. the. connection. via. the. REMOTE. LINK,. the. two. PA8506-V. units. configure.
themselves.automatically.without.making.any.other.settings..The.logo.“12”.will.appear.in.the.
top.right-hand.corner.of.the.main.page.of.the.MUSIC.Menu.of.each.PA8506-V.to.indicate.that.
the.system.is.configured.for.12.zones.(see.figure.opposite)..
Should.the.REMOTE.LINK.be.broken.off,.both.PA8506-V.units.will.signal.the.failure.as.a.“Remote.
Link.Fault”..To.restore.the.standard.6-zone.configuration,.RESET.the.configuration.as.illustrated.
in.point.8.6.6.2.“Restoring.the.6-zone.configuration”.on.page.111.
Note:
Use.Cat..5e.SF/UTP.cable.with.a.braided.shield.
for. connecting. the. two. PA8506-V. units. and.
PAGING.UNITS.to.one.another..
Maximum length of the connecting line:
1km.
5.5.2 Assigning the output zones to the selection controls
.
•.
PA8506-V Units
.
The.six.numerical.keys.on.the.control.panel.of.each.PA8506-V.affect.only.their.respective.output.zones,.so.that.the.two.units.function.
basically.as.two.separate.systems.covering.six.zones.each.
.
•.
PMB132-V and PMB132/12-V remote emergency units
.
By.connecting.one.or.more.remote.emergency.units.to.the.EMERGENCY.UNIT.sockets,.it.is.possible.to.achieve.complete.management.of.
the.12-zone.system..The.emergency.units.can.function.either.in.the.“Local”.mode.or.in.the.“Global”.mode,.thus.adapting.them.to.various.
different.needs.according.to.the.emergency.plan..A.station.in.the.LOCAL.mode.can.only.access.the.six.output.zones.covered.by.the.
PA8506-V.unit.to.which.it.is.connected,.while.a.station.in.the.GLOBAL.mode.can.access.all.12.zones.of.the.system.
For.further.details.on.the.station.programming.modes,.see.point.8.6.4.
Model.PMB132-V.has.only.the.PTT.key.assigned.to.general.switching.(it.may.be.programmable).and.the.programmable.AUX.key.for.sending.
pre-recorded.messages.to.a.pre-defined.set.of.zones..In.addition.to.all.the.functions.available.on.the.PMB132-V,.model.PMB132/12-V.also.has.
a.selection.keypad.with.12.keys,.each.of.which.has.3.LEDs.for.signalling.the.various.operating.statuses.of.the.relevant.output.zones.