H Series Fieldbus Extension Units, Series A (PSSEXT1 & PSSEXT3)
E117P
4
Specifi cations
-
Following are specifi cations for the H Series Fieldbus extension units.
H Series Fieldbus Extension Units
Operating Temperature
IEC 60068-2-1 (Test Ad, Operating Cold),
IEC 60068-2-2 (Test Bd, Operating Dry Heat),
IEC 60068-2-14 (Test Nb, Operating Thermal Shock):
-20 to 60°C (-4 to 140°F)
Storage Temperature
IEC 60068-2-1 (Test Ab, Un-packaged Non-operating Cold),
IEC 60068-2-2 (Test Bb, Un-packaged Non-operating Dry Heat),
-40 to 85°C (-40 to 185°F)
Relative Humidity
IEC 60068-2-30 (Test Db, Un-packaged Non-operating Damp Heat):
5 to 95% non-condensing
Shock
IEC60068-2-27 (Test Ea, Unpackaged Shock):
Operating
30g
Non-operating
50g
Vibration
IEC60068-2-6 (Test Fc, Operating):
5g @ 10 to 500Hz
ESD Immunity
IEC 61000-4-2:
6kV contact discharges
8kV air discharges
Radiated RF Immunity
IEC 61000-4-3:
10V/m with 1kHz sine-wave 80%AM from 30MHz to 2000MHz
10V/m with 200Hz 50% Pulse 100%AM at 900Mhz
10V/m with 200Hz 50% Pulse 100%AM at 1890Mhz
Emissions CSPR
11:
Group 1, Class A
Enclosure Type Rating
Meets IP65/66/67 (when marked)
Mounting Base Screw Torque
#8 screw, 7.5 in. lbs. in Aluminum, 16 in. lbs. in Steel
Certifi cations:
c-UL-us UL Listed Industrial Control Equipment,
(when product is marked)
certifi ed for US and Canada
CE
European Union 89/336/EEC EMC Directive,
compliant
with:
EN 61000-6-4; Industrial Emissions
EN 50082-2; Industrial Immunity
EN 61326; Meas./Control/Lab., Industrial Requirements
EN 61000-6-2; Industrial Immunity
C- Tick Australian Radiocommunications Act, compliant with:
AS/NZS CISPR 11; Industrial Emissions
Extension Unit Application Rules
All the following rules apply for both the PSSEXT1 and PSSEXT3
extension unit.
• For all adapters:
–
Up
to
four
extension units can be used per network adapter.
• The fi rst module after an extension unit must be a PSSSE24A.
– A PSSSE24A is needed:
– if additional backplane power is needed because of module
current consumption, or
– after 2 extension units.
The only exception to this rule is if the modules in the segment
after the extension unit are only PSSTR4M12As. If only this
module is used, NO PSSSE24A is needed. In this case, the Pin
1 on PSSTR4M12A will NOT have 24VDC. Thus load must be
powered by external power. See E109P, Relay Output Module
Instruction Sheet for details.
• The number or mix of modules you use between extension cables
does not matter as long as you do not exceed the rated adapter
or PSSSE24A current output.
Содержание H Series
Страница 135: ...DeviceNet Media Design and Installation Guide...
Страница 144: ...Publication DNET UM072C EN P July 2004 Table of Contents iv...
Страница 170: ...Publication DNET UM072C EN P July 2004 1 26 Get Started Notes...
Страница 194: ...Publication DNET UM072C EN P July 2004 2 24 Identify Cable System Components Notes...
Страница 212: ...Publication DNET UM072C EN P July 2004 3 18 Make Cable Connections Notes...
Страница 238: ...Publication DNET UM072C EN P July 2004 4 26 Determine Power Requirements Notes...
Страница 248: ...Publication DNET UM072C EN P July 2004 5 10 Correct and Prevent Network Problems Notes...
Страница 250: ...Publication DNET UM072C EN P July 2004 A 2 Understand Select NEC Topics Notes...
Страница 263: ......
Страница 267: ...Isysnet Serial Bus System Selection Guide Pneumatic...
Страница 287: ...H Series Fieldbus DeviceNet Adapters PSSCDM12A PSSCDM18PA User Manual...