Elapsed
value
12000 0
1000 to 4999
R100:ON
7000 to 8999
R101:ON
Target value 1
ON set value
1000
Target value 2
OFF set value
9000
Target value 2
ON set value
7000
Target value 1
OFF set value
5000
■
Upper limit control
With the F165 (CAM0) instruction, the control with a specified upper limit can be performed.
The settings for enabling / disabling the upper limit control and the upper limit are specified in
the data table.
Upper limit control: Enable
Upper limit control: Disable
Counting range
0 to Upper limit
Negative min. value to Positive max.
value
Operation
when
exceeding the
counting range
When
added
When the elapsed value exceeds the
upper limit, it returns to 0.
When the elapsed value exceeds the
positive maximum value, it returns to the
negative minimum value.
When
subtracte
d
When the elapsed value falls below 0, it
returns to the upper limit.
When the elapsed value falls below the
negative minimum value, it returns to the
positive maximum value.
■
Data table settings
Operand
Settings
Description
S, S+1
High-speed counter
channel
Upper and lower limit
control
Specify the high-speed counter channel where the cam control is
performed and whether or not to execute the upper and lower limit
control as a hexadecimal constant.
S+2, S+3
Output device type
Specify the device type set for the cam output.
H0: Link relay (L), H1: Internal relay (R), H2: Output relay (Y)
10.4 High-speed Counter Cam Control Instruction
WUME-FPXHPOSG-01
10-21
Содержание FP-XH Series
Страница 2: ... MEMO 2 WUME FPXHPOSG 01 ...
Страница 18: ... MEMO 1 10 WUME FPXHPOSG 01 ...
Страница 30: ... MEMO 3 8 WUME FPXHPOSG 01 ...
Страница 51: ...4 4 Reading Elapsed Values WUME FPXHPOSG 01 4 21 ...
Страница 52: ... MEMO 4 22 WUME FPXHPOSG 01 ...
Страница 88: ... MEMO 5 36 WUME FPXHPOSG 01 ...
Страница 94: ... MEMO 6 6 WUME FPXHPOSG 01 ...
Страница 140: ... MEMO 9 8 WUME FPXHPOSG 01 ...
Страница 193: ... MEMO WUME FPXHPOSG 01 ...
Страница 194: ...Panasonic Industrial Devices SUNX Co Ltd 2020 October 2020 WUME FPXHPOSG 01 ...