2.
Make necessary parameter settings according to the application and press the [OK] button.
The settings will be stored as part of positioning parameter data.
Parameters
Parameter name
Default
(unit)
Settings
Basic
Pulse output method
Pulse/Sign
Pulse/Sign, CW/CCW
Pulse output rotation
direction
CW dir
When selecting Pulse/Sign mode:
CW dir: Select this setting for the case that the
elapsed value is increased when Sign output turns off.
CCW dir: Select this setting for the case that the
elapsed value is increased when Sign output turns on.
When selecting CW/CCW mode:
CW dir: Select this setting for the case that the
elapsed value is increased at the time of CW output.
CCW dir: Select this setting for the case that the
elapsed value is increased at the time of CCW output.
Startup speed
100 (pps)
Set the startup speed common to each operation. This
setting is common to JOG operation, home return, E-point
control, P-point control, C-point control and J-point
control.
Setting range: 1 to 100,000
Positioning repeat count 0
Specify this setting for performing repetitive controls when
using E-point/P-point/C-point control.
4.2 Settings in Configurator PMX
4-10
WUME-FPXHPOSG-01
Содержание FP-XH Series
Страница 2: ... MEMO 2 WUME FPXHPOSG 01 ...
Страница 18: ... MEMO 1 10 WUME FPXHPOSG 01 ...
Страница 30: ... MEMO 3 8 WUME FPXHPOSG 01 ...
Страница 51: ...4 4 Reading Elapsed Values WUME FPXHPOSG 01 4 21 ...
Страница 52: ... MEMO 4 22 WUME FPXHPOSG 01 ...
Страница 88: ... MEMO 5 36 WUME FPXHPOSG 01 ...
Страница 94: ... MEMO 6 6 WUME FPXHPOSG 01 ...
Страница 140: ... MEMO 9 8 WUME FPXHPOSG 01 ...
Страница 193: ... MEMO WUME FPXHPOSG 01 ...
Страница 194: ...Panasonic Industrial Devices SUNX Co Ltd 2020 October 2020 WUME FPXHPOSG 01 ...