10.4 High-speed Counter Cam Control Instruction
10.4.1 [F165 CAM0] High-speed Counter Cam Control Instruction
Performs the cam output up to a maximum of 32 points (ON / OFF) according to the elapsed
value of the high-speed counter.
■
Instruction format
■
Operand
Operand
Settings
S
Starting number of data table
■
Memory area type that can be specified
Operand
WX
WY
WR
WL
SV
EV
DT
LD
I
Constant
Index
modifier
K
H
S
-
-
-
-
-
-
●
-
-
-
-
●
■
Outline of operation
● Performs the cam output up to a maximum of 32 points (ON/OFF) according to the elapsed
value of the high-speed counter in the pattern specified for the data table starting with [S].
The output device can be selected from internal relay, output relay and link relay.
● The ON set value and OFF set value can be arbitrarily specified as a paired target values for
a single cam output regardless of the magnitude of target values or the order for one cam
output. The pattern of ON/OFF varies according to the setting.
10.4 High-speed Counter Cam Control Instruction
10-20