data register DT90052 to OFF→ON→OFF by the near home input. The value in the elapsed
value area during the home return operation differs from the current value.
Home return mode I (Home return by near home input and home input)
When the near home input is enabled, deceleration will be performed, and the pulse output
will stop after the home input. The operation varies according to the setting of the control code
(low byte) described on the next page.
f
t
Fmax
Fmin
Near home input
Home input
Home return mode II (Home return by home input only)
When the home input is enabled, the pulse output will stop. Set the control code (low byte) on
the next page to H20 to H27.
f
t
Fmax
Fmin
Home input
■
Data table settings
S
S+1
S+2
S+3
S+4
S+5
S+6
S+7
S+8
S+9
①
②
③
④
Control code
Initial speed
Fmin(Hz)
Maximum speed
Fmax(Hz)
Acceleration/
deceleration time
t(ms)
Deviation counter clear
signal output time tr(ms)
Operand
Settings
Description
(1)
S, S+1
Control code
Specify the control code by setting the H constant.
7.2 FP-X Compatible Instruction Mode Control Instruction
7-16
WUME-FPXHPOSG-01
Содержание FP-XH Series
Страница 2: ... MEMO 2 WUME FPXHPOSG 01 ...
Страница 18: ... MEMO 1 10 WUME FPXHPOSG 01 ...
Страница 30: ... MEMO 3 8 WUME FPXHPOSG 01 ...
Страница 51: ...4 4 Reading Elapsed Values WUME FPXHPOSG 01 4 21 ...
Страница 52: ... MEMO 4 22 WUME FPXHPOSG 01 ...
Страница 88: ... MEMO 5 36 WUME FPXHPOSG 01 ...
Страница 94: ... MEMO 6 6 WUME FPXHPOSG 01 ...
Страница 140: ... MEMO 9 8 WUME FPXHPOSG 01 ...
Страница 193: ... MEMO WUME FPXHPOSG 01 ...