Settings
Item
Setting example
Axis setting area
Startup speed
1,000 Hz
JOG operation
acceleration time
100 ms
JOG operation
deceleration time
200 ms
JOG operation target
speed
20,000 Hz
■
Configurator PMX settings
■
Sample program
The execution condition is set to be always executed. For details of instructions, refer to
CH No.0
JOG reverse operation starts.
CH No.0
JOG forward operation starts.
R3
K0
F381 JOGST
K0
R4
K0
F381 JOGST
K1
R3
R4
■
Operation at over limit input
Conditions
Direction
Limit status
Operation
At startup
Forward
Over limit input (+): ON
Not executable, Error occurs.
Over limit input (-): ON
Executable
Reverse
Over limit input (+): ON
Executable
Over limit input (-): ON
Not executable, Error occurs.
During
operation
Forward
Over limit input (+): ON
Over limit input (-): ON
Reverse
Over limit input (+): ON
5.2 JOG Operation