Operation diagram
Home return target speed
Home return creep speed
Home return start contact
Near home switch (DOG)
Home switch
Home return done flag
Deviation counter clear signal
BUSY flag
■
Operations of each contact
● The BUSY flags (X28 to X2D), which indicate that the motor is running, will turn ON when the
home return operation starts, and they will turn OFF when the operation completes.
● The deviation counter clear signal will turn ON after the completion of the home return
operation. The ON time is set in the axis setting area of the positioning memory.
● The home return done flags (X48 to X4D), which indicate the completion of home return
operation, will turn ON when the current operation is completed, and they will be held until
any operation of the positioning control, JOG operation and home return operation starts.
The timing of turning ON the flags is on the completion of the home return.
■
Settings
Item
Setting example
Axis setting area
Home return method
DOG method 1
Home return direction
Over limit (-) direction
Home return acceleration time
(ms)
100 ms
Home return deceleration time
(ms)
100 ms
Home return target speed
10000 pps
Home return creep speed
1000 pps
Deviation counter clear time
(ms)
1 ms
5.3 Home Return
WUME-FPXHPOSG-01
5-13
Содержание FP-XH Series
Страница 2: ... MEMO 2 WUME FPXHPOSG 01 ...
Страница 18: ... MEMO 1 10 WUME FPXHPOSG 01 ...
Страница 30: ... MEMO 3 8 WUME FPXHPOSG 01 ...
Страница 51: ...4 4 Reading Elapsed Values WUME FPXHPOSG 01 4 21 ...
Страница 52: ... MEMO 4 22 WUME FPXHPOSG 01 ...
Страница 88: ... MEMO 5 36 WUME FPXHPOSG 01 ...
Страница 94: ... MEMO 6 6 WUME FPXHPOSG 01 ...
Страница 140: ... MEMO 9 8 WUME FPXHPOSG 01 ...
Страница 193: ... MEMO WUME FPXHPOSG 01 ...
Страница 194: ...Panasonic Industrial Devices SUNX Co Ltd 2020 October 2020 WUME FPXHPOSG 01 ...