4.4 Reading Elapsed Values
4.4.1 Elapsed Value (Current Value) Area
● They are stored as 2-word 32-bit data in the axis information area of positioning memory.
● The elapsed value area will be reset when the power supply turns off. It will be held when
switching the mode from RUN to PROG.
■
Counting range of elapsed value (current value) area
Section
Range
For single axis
control
-1,073,741,824 to 1,073,741,823
For interpolation
axis control
-8,388,608 to +8,388,607
4.4.2 Elapsed Value (Current Value) Area
Use [F384 PTBLR] positioning parameter read instruction for reading elapsed values.
■
Instruction format
Operand
Settings
Specification for reading the elapsed value area
S1
Specification of channel numbers and
positioning memory area
H1
Specify the axis information area of CH0.
H101
Specify the axis information area of CH1.
H201
Specify the axis information area of CH2.
H301
Specify the axis information area of CH3.
H401
Specify the axis information area of CH5.
H501
Specify the axis information area of CH5.
S2
Starting address of positioning memory
(Offset address)
K2 Specify the offset address.
n
No. of read words
K2 Specify two words.
D
Operation memory storing read data
Specify an arbitrary memory.
■
Sample program
The following sample shows the program when reading the elapsed value (current value) of
CH3 to the data registers DT300 to DT301. For details of instructions, refer to
4.4 Reading Elapsed Values
4-20
WUME-FPXHPOSG-01
Содержание FP-XH Series
Страница 2: ... MEMO 2 WUME FPXHPOSG 01 ...
Страница 18: ... MEMO 1 10 WUME FPXHPOSG 01 ...
Страница 30: ... MEMO 3 8 WUME FPXHPOSG 01 ...
Страница 51: ...4 4 Reading Elapsed Values WUME FPXHPOSG 01 4 21 ...
Страница 52: ... MEMO 4 22 WUME FPXHPOSG 01 ...
Страница 88: ... MEMO 5 36 WUME FPXHPOSG 01 ...
Страница 94: ... MEMO 6 6 WUME FPXHPOSG 01 ...
Страница 140: ... MEMO 9 8 WUME FPXHPOSG 01 ...
Страница 193: ... MEMO WUME FPXHPOSG 01 ...
Страница 194: ...Panasonic Industrial Devices SUNX Co Ltd 2020 October 2020 WUME FPXHPOSG 01 ...