For Long and Trouble-Free Operation: Error Messages
221
F
o
r Lon
g an
d T
roub
le
-F
ree O
p
e
rati
o
n
Playlist
DIFFERENT SYSTEM
FREQUENCY!
Some files have a different system frequency.
Use only files with the same system frequency.
DURATION
LIMITATION!
The selected process cannot be performed
because playlist duration exceeds 24 hours.
Delete data to reduce the duration to less than 24
hours to process.
ILLEGAL CLIP IN
SELECTION!
Duration of 24PN clips is illegal.
Set 24PN clips in 4-frame units.
ILLEGAL FILE!
The playlist is not in a format that can be loaded
into the unit.
Use a playlist file in a format that can be loaded into
the unit.
INVALID PLAYER
RANGE
Player IN or OUT point is set beyond the range for
recorder IN or OUT point.
Change the recorder IN or OUT point to fit within the
player source.
INVALID RECORDER
RANGE
Recorder IN or OUT point is set beyond the range
for player IN or OUT point.
Change the player IN or OUT point to fit within the
recorder source.
LACK OF REC
CAPACITY!
The card selected for Edit Copy does not have
enough capacity.
Insert a card with sufficient capacity.
NO CARD!
The specified card does not exist.
Insert the card before attempting to process it.
NO FILE!
The specified file does not exist.
Use SAVE AS to save or insert a normally operating
card.
NO SPACE!
There is not enough space on the card.
NOT AVAILABLE
FORMAT!
Cannot edit data in the current format.
Use a compatible playlist format.
NOT SELECTED!
No clip is selected.
Select the clip in the player thumbnail screen.
NUMBER OF EVENT
LIMITATION!
The number of events on a track has reached the
upper limit.
The upper limit of the number of events on each
track is 100. Operate within this limit.
NUMBER OF FILE
LIMITATION!
The number of playlist files has reached the
upper limit.
One card can store up to 999 playlist files. Delete
files no longer needed or use a new card.
READ ONLY
PLAYLIST VERSION!
The playlist file is opened as read only because it
is in a different version.
Playlists created on the AJ-SPD850, AJ-HPM100,
AJ-HPM110 or AJ-HPS1500 can only be opened as
read only files. To edit such files on this unit save
them out.
R-OUT POINT IS NOT
AVAILABLE IN
INSERT MODE
An insert edit cannot use a recorder OUT point.
Select some point other than the recorder OUT point
in editing.
WRITE PROTECTED!
The specified card is write protected.
Insert write-enabled media.
Error information
Error
Description
Operation
No.
Message
E-30
TURN POWER OFF
Displayed when an error occurs in reading and writing card data.
To continue operation, turn the power off and then back on again.
STOP
E-37
COMM ERROR
Displayed when a system controller command was not complied to.
To continue operation, turn the power off and then back on again.
STOP
E-38
SYSTEM ERROR
Displayed when the fan motor stops.
To continue operation, turn the power off and then back on again.
STOP
E-55
OPT SYS ERROR
Displayed when an AJ-YCX250G AVCHD codec board (optional) malfunctions. Turn
the power off and then back on again.
STOP
E-56
OPT NOT RESPONSE
Displayed when an AJ-YCX250G AVCHD codec board (optional) does not respond
to communications. Turn the power off and then back on again.
STOP
E-57
OPT HALT
Displayed when communications from an AJ-YCX250G AVCHD codec board
(optional) cannot be updated. Turn the power off and then back on again.
STOP
Item
Message
Description
Measure