For Long and Trouble-Free Operation: Error Messages
217
F
o
r Lon
g an
d T
roub
le
-F
ree O
p
e
rati
o
n
*
2
Operation continues but normal recording or playback may not be possible.
*
3
An attempt to start recording causes the button to temporarily light. It goes out a few seconds later and no recording is made.
Display
Description
Deck operation
No
Character code
71
RUNDOWN
CARD<******>
The maximum number of overwrites has been exceeded. (* indicates the slot number
where the error occurred.) This P2 card should be replaced.
Operation
continues
*
2
75
HDD INTERMITTENT
Displayed for 3 seconds when a dropout due to reduced hard disk performance occurs
during hard disk playback for monitoring purposes.
Use a faster hard disk.
Operation
continues
93
INVALID TC MODE
Appears during playback when the time code has been recorded in drop frame mode.
The video output is distorted and audio output is muted at the drop point of the time code.
Check the playback clip. Playing back a 24p frame-rate clip requires that the time code
be recorded in non-drop frame mode. Appears when the time code in an HD SDI input is
in the drop frame mode during EE or recording. Normal recording will not be possible
under these conditions. Check signal input to the unit. Set the input time code to non-drop
frame mode.
Operation
continues
95
INVALID EMBEDDED
TC
Displayed while synchronizing recorded video frames to the time code of a signal input
to the HD SDI connector when that time code is not advancing at 1× normal speed. (When
“SLTC” is selected in setup menu No. 032 (REC REF) or 29.97, 59-23, 60-24, 25 or 60-25
is selected in setup menu No. 25 (SYSTEM FREQ).)
Operation
continues
96
INVALID TC
SEQUENCE
Appears during playback when frame rate data in user bit cannot be detected or when
the playback time code is not continuous. The video output is distorted and audio output
is muted in sections where the time code is not continuous. Check the playback clip.
Appears during EE or recording when frame rate data cannot be detected in the user bit
data in an HD SDI input or when the input time code is not continuous. Normal recording
will not be possible under these conditions. Check signal input to the unit. Input signals
with a matching time code and pull-down sequence.
Operation
continues
97
NO ACTIVE FRAME
Appears when active frame data cannot be detected in the user bits in the HD SDI input
during EE or recording. Normal recording will not be possible under these conditions.
Check signal input to the unit. The input signal must contain the active frame data from a
variable frame-rate camera. (Appears when 29.97, 59-23, 60-24 or 60-25 is set in setup
menu No. 25 (SYSTEM FREQ) and setup menu No 040 (VFR REC) is set to ON.)
Recording is
disabled
*
3
Operation
continues during
recording
98
INVALID FRAME
RATE
Appears when active frame data detected from the user bit in the HD SDI input during EE
and recording exceeds 50p. Normal recording is not possible under these conditions.
When SYSTEM FREQ is set to 60-25, set the frame rate on a variable frame-rate camera
to 50p or less. Appears when SYSTEM FREQ is set to 60-25 and VFR REC is set to ON.
Operation
continues
23.98Hz
24Hz
59-23Hz
60-24Hz
60-25Hz
only
29.97Hz
59-23Hz
60-24Hz
25Hz
60-25Hz
only
23.98Hz
24Hz
59-23Hz
60-24Hz
60-25Hz
only
29.97Hz
59-23Hz
60-24Hz
60-25Hz
only
60-25Hz
only