Setup: Item Settings
This function determines unit mode after a cue-up operation.
•
XX
indicates factory default settings.
This menu sets the time code.
•
XX
indicates factory default settings.
EDIT
Item
Setting
Settings and brief function description
FR
No.
SUPER
DISP.
FR
No.
SUPER
DISP.
315
AFTER CUE-UP
0000
0001
0002
STOP
STILL
STILL2
Selects unit mode after cue-up operation.
0: STOP mode
1: Still picture (SHTL +0.0) mode
2: Still picture (VAR +0.0) mode
TIME CODE
Item
Setting
Settings and brief function description
FR
No.
SUPER
DISP.
FR
No.
SUPER
DISP.
500
VITC BLANK
0000
0001
BLANK
THRU
Specifies whether or not a VITC signal will be output at the positions selected in setup
menu No. 501 (VITC POS-1) and No. 502 (VITC POS-2) during playback.
0: VITC signals are not output.
1: VITC signals are output.
NOTE:
• This setting is available only during analog composite output and SD SDI output.
• In EE mode, the input signal is output with the VITC signal.
501
VITC POS-1
When set to
59.94 Hz, 29.97 Hz
Specifies the position where the VITC signal will be inserted.
NOTE:
• You cannot select the same line as in setup menu No. 502 (VITC POS-2).
• The VITC signal is not output when 23.98, 24, 59-23, 60-24, or 60-25 is selected in
setup menu No.25 (SYSTEM FREQ).
• You cannot select the same line as in setup menu No.692 (UMID POS).
• This setting is available only during analog composite output and SD SDI output.
• This setting does not return to the factory default even if you press the SEARCH button
and RESET button simultaneously.
0000
|
0006
|
0010
10L
|
16L
|
20L
When set to
50 Hz, 25 Hz
0000
|
0004
|
0015
7L
|
11L
|
22L
59.94Hz
50Hz
29.97Hz
25Hz
only
59.94Hz
50Hz
29.97Hz
25Hz
only