If “Soft Stop” is made “TRUE” in the “Etch Parameters” menu, the Xetch will allow the current cycle to
finish before ending the entire etch. If the “STOP” button is pressed twice, the Xetch will prompt the
above menu (See also “Soft Stop” on page 78). Choosing “Yes, Hard Stop” will end the etch cycle
immediately and return the user to the main menu. If “No, Keep Waiting” is chosen only the current
cycle will be completed before returning the user to the main menu.
At the bottom of the screen there is a figure labeled ETA. This feature displays the expected completion
time. The ETA is continuously updated during the process run.
Once the desired recipe settings have been chosen then etching can be initiated. By pressing the “Start
Etch” button at the bottom left, the set values are stored and used to complete the desired etching
sequence. At this point all of the controls will be disabled except for the stop button.
Содержание SPTS Xactix e1 Series
Страница 1: ...Manual Version e1 4 3 0 ae R3 2015 04 Xactix e1 Series System Manual ...
Страница 38: ...Manual Version e1 4 3 0 ae R3 Page 36 Figure 23 Shroud ventillation connection Shroud ventilation connection ...
Страница 40: ...Manual Version e1 4 3 0 ae R3 Page 38 Figure 26 Showerhead stop installed ...
Страница 48: ...Manual Version e1 4 3 0 ae R3 Page 46 Figure 29 Chamber ventilation shroud moved to back ...
Страница 49: ...Manual Version e1 4 3 0 ae R3 Page 47 Figure 30 Chamber ventilation shroud pulled forward ...
Страница 83: ...Manual Version e1 4 3 0 ae R3 Page 81 ...
Страница 86: ...Manual Version e1 4 3 0 ae R3 Page 84 ...
Страница 101: ...Manual Version e1 4 3 0 ae R3 Page 99 Figure 46 Gax box heater ...
Страница 103: ...Manual Version e1 4 3 0 ae R3 Page 101 Figure 48 Vacuum interlock switches Chamber vacuum switch Main vacuum switch ...
Страница 109: ...Manual Version e1 4 3 0 ae R3 Page 107 9 Set number of purge cycles to 0 and Hard Pump Time to 10 minutes ...