If it is necessary to adjust the tilt of the tray, loosen the jam nuts on each support and
unscrew or screw the four threaded rods into the linkages to adjust the tilt until the
containment drains properly. Reduce the length of a rod if that corner is too high, and
lengthen the rod if the corner is too low. Tighten the jam nuts once the tilt creates a
sufficient slope to make the containment drain. Make sure that the upper containment
does not interfere with the lower tray after it has been adjusted.
5.5.3
Containment Safety Reminders
Never operate the machine with any doors open or safety guards removed, disabled or
bypassed.
Keep hands and all other body parts outside of the machine when moving any axis or
spindle.
The safety guidelines in section 4.3 should always be observed to prevent injury.
5.6
Slurry System and Chiller
5.6.1
Chiller Basics
The Chiller On/Off switch should always be in the “On” position. The CNC will control the power state of
the chiller automatically when Servos are on. Temperature is factory set and is not to be adjusted.
TURN OFF POWER TO THE CHILLER BEFORE ANY CHILLER SERVICE OR CLEANING AND BEFORE
DISCONNECTING ANY CHILLER LINES THROUGHOUT THE MACHINE.
Figure 5-11: Chiller Unit
Temperature
Control
Chiller
On/Off
Fill Port
Fluid Level
Gage
Air Filter