5.5
Containment
5.5.1
Upper Containment
The upper containment of the machine is stationary. Maintenance items for the upper containment can
be found in Section 9: Machine Maintenance.
5.5.2
Lower Containment
The lower containment tray moves with the x- and y-axes of the machine. The lower tray is fitted with
quick-disconnect hose fittings for easy removal and cleaning. The hose fittings automatically lock when
the handles are in the “closed” position (See Figure 5-14). Depress the red button to release them.
Figure 5-10: Lower Containment Tray Stabilizers
The containment is set up to drain properly before each install. This may change with regular machine
use. If drainage problems occur, the following methods should be used to correct the issue:
Check that no blockages exist along in the drain hoses.
Make sure that the containment drain hose coming out of the machine going to the input on
the slurry pump does not sag lower than the lid of the containment.