10-26
H
Function Group 4 (n120 through n179)
Param-
eter
No.
Regis-
ter No.
(Hex)
Name
Description
Set-
ting
range
Unit
of
set-
ting
Default
setting
Changes
during
opera-
tion
Ref-
er-
ence
page
n120
0178
Frequency
reference 9
Sets the internal frequency refer-
ences.
0.00
Hz to
0.01
Hz
(C
0.00
Yes
5-19
n121
0179
Frequency
reference 10
e ces
* These frequency references are
selected with multi-step speed ref-
o
max.
(Cha
nge-
able
0.00
Yes
5-19
n122
017A
Frequency
reference 11
selected with multi step speed ref
erences (multi-function inputs).
See the reference pages for the
relationship bet een m lti step fre
able
with
n035
0.00
Yes
5-19
n123
017B
Frequency
reference 12
g
relationship between multi-step fre-
quency references and frequency
references
n035
set-
tings)
0.00
Yes
5-19
n124
017C
Frequency
reference 13
references.
tings)
0.00
Yes
5-19
n125
017D
Frequency
reference 14
0.00
Yes
5-19
n126
017E
Frequency
reference 15
0.00
Yes
5-19
n127
017F
Frequency
reference 16
0.00
Yes
5-19
n128
0180
PID control
selection
Selects the PID control method.
0: PID control disabled.
1 to 8: PID control enabled.
* The derivative control method (i.e.,
the derivative control of the devi-
ation or detected value), the addi-
tion of the frequency reference,
and the positive or negative char-
acteristics of PID control are
selectable.
0 to 8
1
0
No
6-16
n129
0181
Feedback
value adjust-
ment gain
Sets the value by which the feedback
value is multiplied.
* This parameter is used for adjust-
ing the target and detected values
so that they will have the same
input level.
0.00 to
10.00
0.01
1.00
Yes
6-16
n130
0182
Proportional
(P) gain
Sets the proportional (P) gain for PID
control.
* PID control is disabled with this
parameter set to 0.0.
0.0 to
25.0
0.1
1.0
Yes
6-16
n131
0183
Integral (I)
time
Sets the integral (I) time for PID con-
trol.
* Integral control is disabled with this
parameter set to 0.0.
0.0 to
360.0
0.1 s
1.0
Yes
6-16
n132
0184
Derivative (D)
time
Sets the derivative (D) time for PID
control.
* Derivative control is disabled with
this parameter set to 0.0.
0.00 to
2.50
0.01
s
0.00
Yes
6-17
n133
0185
PID offset
adjustment
This parameter is for the offset adjust-
ment of all PID control.
Sets the parameter as a percentage
based on the maximum frequency as
100%.
–100
to 100
1%
0
Yes
6-17
List of Parameters
Chapter 10
Содержание SYSDRIVE 3G3MV-A2001
Страница 1: ...Cat No I527 E1 04 USER S MANUAL SYSDRIVE 3G3MV Multi function Compact Inverter...
Страница 2: ......
Страница 3: ...USER S MANUAL Multi function Compact Inverter SYSDRIVE 3G3MVSERIES...
Страница 18: ......
Страница 23: ...Chapter 1 Overview 1 1 Functions 1 2 Nomenclature 1 3 New Features 1...
Страница 32: ......
Страница 33: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Страница 74: ......
Страница 75: ...Chapter 3 Preparing for Operation and Monitoring 3 1 Nomenclature 3 2 Parameter Copy and Verify Function 3...
Страница 93: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Страница 102: ......
Страница 142: ......
Страница 242: ......
Страница 268: ......
Страница 269: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9...
Страница 293: ...9 25 D 3G3MV PRS2030V PRS3020V Four M4 holes for Inverter mounting use Three 5 dia holes Specifications Chapter 9...
Страница 294: ...9 26 D 3G3MV PRS2050V Four M5 holes for Inverter mounting use Three 6 dia holes Specifications Chapter 9...
Страница 297: ...9 29 D 3G3MV PRS1040V Three 5 dia holes Four M4 holes for Inverter mounting use Specifications Chapter 9...
Страница 303: ...Chapter 10 List of Parameters 10...
Страница 337: ...Chapter 11 Using the Inverter for a Motor 11...
Страница 343: ......
Страница 344: ...I527 E1 04...