6-24
•
The Inverter cannot maintain rated output current with the carrier frequency set to a value higher than
the default one.
The following table shows the default settings and the reduced rated output currents resulting from a
higher setting for the carrier frequency for each Inverter model.
When the carrier frequency is set to a higher value than the default setting, use the Inverter at a current
less than the reduced rated output current.
Voltage
Model 3G3MV-
Default setting
Rated output
current (A)
Set to 3
Reduced rated
output current
(A)
Set to 4
Reduced rated
output current
(A)
3-phase
200 V
A2001
4 (10 kHz)
0.8
←
←
p
200 V
A2002
4 (10 kHz)
1.6
←
←
A2004
4 (10 kHz)
3.0
←
←
A2007
4 (10 kHz)
5.0
←
←
A2015
3 (7.5 kHz)
8.0
←
7.0
A2022
3 (7.5 kHz)
11.0
←
10.0
A2037
3 (7.5 kHz)
17.5
←
16.5
A2055
3 (7.5 kHz)
25.0
←
23.0
A2075
3 (7.5 kHz)
33.0
←
30.0
Single-phase
V
AB001
4 (10 kHz)
0.8
←
←
g
p
200 V
AB002
4 (10 kHz)
1.6
←
←
AB004
4 (10 kHz)
3.0
←
←
AB007
4 (10 kHz)
5.0
←
←
AB015
3 (7.5 kHz)
8.0
←
7.0
AB022
3 (7.5 kHz)
11.0
←
10.0
AB037
3 (7.5 kHz)
17.5
←
16.5
3-phase
V
A4002
3 (7.5 kHz)
1.2
←
1.0
p
400 V
A4004
3 (7.5 kHz)
1.8
←
1.6
A4007
3 (7.5 kHz)
3.4
←
3.0
A4015
3 (7.5 kHz)
4.8
←
4.0
A4022
3 (7.5 kHz)
5.5
←
4.8
A4030
3 (7.5 kHz)
7.2
←
6.3
A4037
3 (7.5 kHz)
8.6
←
8.1
A4055
3 (7.5 kHz)
14.8
←
14.8 (See note.)
A4075
3 (7.5 kHz)
18.0
←
17.0
Note
The rated output current can be output without reduction.
n175
Low Carrier Frequency at Low
Speed
Register
01AF Hex
Changes during
operation
No
Setting
range
0, 1
Unit of
setting
1
Default setting
0
(See
note.)
Note
For 5.5- and 7.5-kW Inverters, the default setting is “1” (enable).
Advanced Operation
Chapter 6
Содержание SYSDRIVE 3G3MV-A2001
Страница 1: ...Cat No I527 E1 04 USER S MANUAL SYSDRIVE 3G3MV Multi function Compact Inverter...
Страница 2: ......
Страница 3: ...USER S MANUAL Multi function Compact Inverter SYSDRIVE 3G3MVSERIES...
Страница 18: ......
Страница 23: ...Chapter 1 Overview 1 1 Functions 1 2 Nomenclature 1 3 New Features 1...
Страница 32: ......
Страница 33: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Страница 74: ......
Страница 75: ...Chapter 3 Preparing for Operation and Monitoring 3 1 Nomenclature 3 2 Parameter Copy and Verify Function 3...
Страница 93: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Страница 102: ......
Страница 142: ......
Страница 242: ......
Страница 268: ......
Страница 269: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9...
Страница 293: ...9 25 D 3G3MV PRS2030V PRS3020V Four M4 holes for Inverter mounting use Three 5 dia holes Specifications Chapter 9...
Страница 294: ...9 26 D 3G3MV PRS2050V Four M5 holes for Inverter mounting use Three 6 dia holes Specifications Chapter 9...
Страница 297: ...9 29 D 3G3MV PRS1040V Three 5 dia holes Four M4 holes for Inverter mounting use Specifications Chapter 9...
Страница 303: ...Chapter 10 List of Parameters 10...
Страница 337: ...Chapter 11 Using the Inverter for a Motor 11...
Страница 343: ......
Страница 344: ...I527 E1 04...