10-25
Para
me-
ter
No.
Ref-
er-
ence
page
Chan-
ges dur-
ing
opera-
tion
Defa
ult
set-
ting
Unit
of
set-
ting
Set-
ting
range
Description
Name
Reg-
ister
No.
(Hex)
n115
0173
Stall pre-
vention
level auto-
matic sup-
pression
selection
Selects whether or not to automatically de-
crease the level for stall prevention during op-
eration if the frequency lies in a constant out-
put range exceeding the frequency set in n013
for max. voltage frequency (a range greater
than the rated motor frequency).
0: Automatic suppression function disabled
(the value of n094 is valid for any frequency)
1: Automatic suppression function enabled.
* The operation level is decreased by n094
×
(max. voltage frequency/output frequency).
* The stall prevention function during opera-
tion operates according to the acceleration/
deceleration time set in n116.
0, 1
1
0
No
6-29
n116
0174
Stall pre-
vention ac-
celeration/
decelera-
tion time
setting
Sets the acceleration/deceleration time for the
stall prevention function during operation.
0: Accelerates or decelerates according to ac-
celeration/deceleration time 1 or 2, whichev-
er is selected.
1: Accelerates or decelerates according to ac-
celeration/deceleration time 2 (n021/n022).
* When a faster (or slower) acceleration/de-
celeration time is desired, set this parameter
to “1” and set the desired acceleration/de-
celeration time for stall prevention operation
in acceleration/deceleration time 2.
0, 1
1
0
No
6-30
n117
0175
Undertor-
que detec-
tion func-
tion selec-
tion
0: Undertorque detection disabled
1: Undertorque detection only when speed
coincides and operation continues (UL3
Warning)
2: Undertorque detection only when speed
coincides and output turned OFF (UL3
Fault)
3: Undertorque always detected and operation
continues (UL3 Warning)
4: Undertorque always detected and output
turned OFF (UL3 Fault)
0 to 4
1
0
10
(See
note.)
No
6-32
n118
0176
Undertor-
que detec-
tion level
Used to set undertorque detection level.
Detection from output torque: Set as a
percentage based on the rated motor torque as
100%.
Detection from output current: Set as a
percentage based on the rated Inverter output
current as 100%.
0 to
200
1%
10%
10
(See
note.)
No
6-33
n119
0177
Undertor-
que detec-
tion time
Used to set the detection time for undertorque.
Undertorque will be detected if a torque that is
equal to or less than the undertorque detection
level continues for the time set here.
0.1 to
10.0
0.1 s
0.1 s
10
(See
note.)
No
6-34
Note
These parameters are available on 200-V/400-V, 4.0-kW (or less) Inverters (software version
VSP010024 or higher) or 5.5-kW/7.5-kW Inverters (VSP010104 or higher).
List of Parameters
Chapter 10
Содержание SYSDRIVE 3G3MV-A2001
Страница 1: ...Cat No I527 E1 04 USER S MANUAL SYSDRIVE 3G3MV Multi function Compact Inverter...
Страница 2: ......
Страница 3: ...USER S MANUAL Multi function Compact Inverter SYSDRIVE 3G3MVSERIES...
Страница 18: ......
Страница 23: ...Chapter 1 Overview 1 1 Functions 1 2 Nomenclature 1 3 New Features 1...
Страница 32: ......
Страница 33: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Страница 74: ......
Страница 75: ...Chapter 3 Preparing for Operation and Monitoring 3 1 Nomenclature 3 2 Parameter Copy and Verify Function 3...
Страница 93: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Страница 102: ......
Страница 142: ......
Страница 242: ......
Страница 268: ......
Страница 269: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9...
Страница 293: ...9 25 D 3G3MV PRS2030V PRS3020V Four M4 holes for Inverter mounting use Three 5 dia holes Specifications Chapter 9...
Страница 294: ...9 26 D 3G3MV PRS2050V Four M5 holes for Inverter mounting use Three 6 dia holes Specifications Chapter 9...
Страница 297: ...9 29 D 3G3MV PRS1040V Three 5 dia holes Four M4 holes for Inverter mounting use Specifications Chapter 9...
Страница 303: ...Chapter 10 List of Parameters 10...
Страница 337: ...Chapter 11 Using the Inverter for a Motor 11...
Страница 343: ......
Страница 344: ...I527 E1 04...