7-36
D
Sequence
•
When repeating actions to give the RUN command and frequency reference to the Inverter and read
the status of the Inverter, for example, the actions can be registered as one sequence, or more than
one if necessary. In
7-9-4 Creating a Project File
, an example is shown with all actions registered as a
single sequence.
•
A sequence may include the following parameters.
Parameter
Description
Transmission control
parameter
Set the method of control, such as flow control.
Note
Select only model control for communications with the 3G3MV.
Link word
Set the area for sharing the data between the Programmable Controller and
Communications Board.
Note
In
7-9-4 Creating a Project File
, an example is shown without such an area set.
Monitor time
Set the periods to monitor the transmission and reception steps with timers Tr, Tfr,
and Tfs.
Note
Set a period of approximately 0.5 s each for communications with the 3G3MV.
Response notify
method
A method to write reception data to the I/O memory of the Programmable
Controller.
Note
Select “notify by scan” for communications with the 3G3MV.
CPU Unit
PMCR
instruction
Communications Board
Step 00
DSR message
(Write the RUN command and
frequency reference.)
Response
Step 01
DSR message
Inverter status read
Response
(Inverter status)
3G3MV
Sequence 000
D
Step
•
In a single step, a DSR message is sent and a response for the DSR message is received. A step may
not include a response if it is a broadcast message.
•
In the case of repetitive actions to issue the RUN command and frequency reference to the Inverter
and read the status of the Inverter, for example, the actions to give the RUN command and frequency
reference is one step. The reason is that these register numbers are consecutive and can be sent with
a single DSR message. The action to read the status of the Inverter is another step.
•
A step includes a command and a maximum of two messages.
The above example uses the Send & Recv command. The DSR message and response are both mes-
sages.
•
A step may include the following parameters.
Communications
Chapter 7
Содержание SYSDRIVE 3G3MV-A2001
Страница 1: ...Cat No I527 E1 04 USER S MANUAL SYSDRIVE 3G3MV Multi function Compact Inverter...
Страница 2: ......
Страница 3: ...USER S MANUAL Multi function Compact Inverter SYSDRIVE 3G3MVSERIES...
Страница 18: ......
Страница 23: ...Chapter 1 Overview 1 1 Functions 1 2 Nomenclature 1 3 New Features 1...
Страница 32: ......
Страница 33: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Страница 74: ......
Страница 75: ...Chapter 3 Preparing for Operation and Monitoring 3 1 Nomenclature 3 2 Parameter Copy and Verify Function 3...
Страница 93: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Страница 102: ......
Страница 142: ......
Страница 242: ......
Страница 268: ......
Страница 269: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9...
Страница 293: ...9 25 D 3G3MV PRS2030V PRS3020V Four M4 holes for Inverter mounting use Three 5 dia holes Specifications Chapter 9...
Страница 294: ...9 26 D 3G3MV PRS2050V Four M5 holes for Inverter mounting use Three 6 dia holes Specifications Chapter 9...
Страница 297: ...9 29 D 3G3MV PRS1040V Three 5 dia holes Four M4 holes for Inverter mounting use Specifications Chapter 9...
Страница 303: ...Chapter 10 List of Parameters 10...
Страница 337: ...Chapter 11 Using the Inverter for a Motor 11...
Страница 343: ......
Страница 344: ...I527 E1 04...