6-10
Set Values
•
Set the range of probe operation voltage in percentage based on the rated motor voltage as 100%.
•
Normally, the default setting does not need to be changed.
•
If the fluctuation of speed in probe operation is large, decrease the set value. If the response of the
Inverter in probe operation is slow, increase the set value.
Control voltage step (%)
Inverter output voltage (%)
n161
Power Detection Width for Probe
Operation Switching
Register
01A1 Hex
Changes during
operation
No
Setting
range
0 to 100 (%)
Unit of
setting
1%
Default setting
10
Set Values
•
Set this parameter to the detection width of power that sets the Inverter to probe operation. When the
fluctuation of power is within the detection width, the Inverter will be in probe operation.
•
Set the width in percentage based on the power to be detected as 100%.
•
Normally, the default setting does not need to be changed.
•
The Inverter will operate with a power detection width of 10% if the value is set to 0.
n162
Power Detection Filter Constant
Register
01A2 Hex
Changes during
operation
No
Setting
range
0 to 255
Unit of
setting
1 (4 ms)
Default setting
5
Set Values
•
Set this parameter to the filter time constant of the power detection block of the Inverter operating in
probe operation.
Filter time constant (ms) = Set value in n162 x 4 (ms)
•
Normally, the default setting does not need to be changed.
•
The Inverter will operate with a time constant of 20 ms if the value is set to 0.
Advanced Operation
Chapter 6
Содержание SYSDRIVE 3G3MV-A2001
Страница 1: ...Cat No I527 E1 04 USER S MANUAL SYSDRIVE 3G3MV Multi function Compact Inverter...
Страница 2: ......
Страница 3: ...USER S MANUAL Multi function Compact Inverter SYSDRIVE 3G3MVSERIES...
Страница 18: ......
Страница 23: ...Chapter 1 Overview 1 1 Functions 1 2 Nomenclature 1 3 New Features 1...
Страница 32: ......
Страница 33: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Страница 74: ......
Страница 75: ...Chapter 3 Preparing for Operation and Monitoring 3 1 Nomenclature 3 2 Parameter Copy and Verify Function 3...
Страница 93: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Страница 102: ......
Страница 142: ......
Страница 242: ......
Страница 268: ......
Страница 269: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9...
Страница 293: ...9 25 D 3G3MV PRS2030V PRS3020V Four M4 holes for Inverter mounting use Three 5 dia holes Specifications Chapter 9...
Страница 294: ...9 26 D 3G3MV PRS2050V Four M5 holes for Inverter mounting use Three 6 dia holes Specifications Chapter 9...
Страница 297: ...9 29 D 3G3MV PRS1040V Three 5 dia holes Four M4 holes for Inverter mounting use Specifications Chapter 9...
Страница 303: ...Chapter 10 List of Parameters 10...
Страница 337: ...Chapter 11 Using the Inverter for a Motor 11...
Страница 343: ......
Страница 344: ...I527 E1 04...