Shifting Input Values
Section 4-1
Two-point shift
• Separate shift values can be set for the upper limit and lower limit of the
sensor input range for an infrared sensor as well as for a thermocouple or
platinum resistance thermometer with the “input shift type” set to INS2. If
different shift values are set for the upper limit and lower limit, then the
slope of the line will be different before and after applying the input shift.
For example, if the upper-limit value is set to 2
°
C and the lower-limit value
is set to 1
°
C, the input temperature will be shifted by 1.5
°
C for a 50%
input, i.e., by the average of the upper-limit and lower-limit values.
• Set the upper-limit value in the “upper-limit temperature input shift value”
parameter and the lower-limit value in the “lower-limit temperature input
shift value” parameter.
4-1-2
How to Calculate Input Shift Values for a 2-point Shift
When an ES1B Infrared Temperature Sensor is connected to the E5CZ, an
offset of several degrees to several tens of a degree can occur.
For this reason, offset the readout value using a 1-point or 2-point shift as
described in this section. This offset occurs because a bias current for detect-
ing a Controller sensor error flows to the output impedance of the infrared
temperature sensor.
Preparations
1,2,3...
1.
Set a temperature range matching the input specifications of the infrared
temperature sensor. (The ES1B can be used with the E5AZ only for a ther-
mocouple/resistance thermometer Universal-input type input.)
2.
Prepare a thermometer capable of measuring the temperature of the con-
trol target as shown in
Figure 1
so that a 1-point shift or 2-point shift can
be carried out.
3.
When ES1B is used, provide a separate power supply for the Infrared
Temperature Sensors.
insh
insl
Upper-limit
temperature
input shift value
Lower-limit
temperature
input shift value
0
100
Temperature
Upper limit
Lower limit
Before shifting
After shifting
Input
Upper-limit temperature
input shift value
Lower-limit temperature
input shift value
Содержание E5AZ
Страница 2: ...E5CZ E5CZ U E5AZ E5EZ Digital Temperature Controller User s Manual Produced September 2008 ...
Страница 3: ...iv ...
Страница 23: ...xxiv ...
Страница 53: ...30 Using the Support Software Port Section 2 3 ...
Страница 79: ...56 Using HB and HS Alarms Section 3 10 ...
Страница 115: ...92 Output Adjustment Functions Section 4 14 ...
Страница 173: ...150 Communications Setting Level Section 5 8 ...
Страница 205: ...182 Index precautions 22 terminal arrangement 21 terminals 21 ...