Specifications
Ratings
Note
(1) For the setting ranges for each sensor input, see page 172.
(2) When connecting the ES2, connect it 1:1.
Supply voltage
100 to 240 VAC, 50/60 Hz
24 VAC, 50/60 Hz/24 VDC
Operating voltage range
85 to 110% of rated supply voltage
Power consump-
tion
E5CZ
7.5 VA
5.5 VA/3.5W
E5CZ-U
6 VA
4.5VA/2.5W
E5AZ
8.5 VA
6 VA/4 W
E5EZ
8.5 VA
6 VA/4 W
Sensor input (See note 1.)
Temperature input type
Thermocouple: K, J, T, E, L, U, N, R, S, B
Platinum resistance thermometer: Pt100, JPt100
Infrared temperature sensor: 10 to 70
°
C, 60 to 120
°
C, 115 to 165
°
C, 140 to 260
°
C
Voltage input: 0 to 50 mV
Controllers with Analog Inputs
Current input: 4 to 20 mA, 0 to 20 mA (Input impedance: 150
Ω
max.)
Voltage input: 1 to 5 V, 0 to 5 V, 0 to 10 V (Input impedance: 1 M
Ω
max.) (See note 2.)
Control output
Relay output
E5CZ
Relay output:
SPST-NO, 250 VAC, 3 A (resistive load), electrical dura-
bility: 100,000 operations
Min. applicable load: 5 V, 10 mA
E5CZ-U
SPDT, 250 VAC, 3A (resistive load), electrical durability:
100,000 operations
Min. applicable load 5 V 10 mA
E5AZ
E5EZ
Relay output:
SPST-NO, 250 VAC, 5 A (resistive load), electrical dura-
bility: 100,000 operations
Min. applicable load: 5 V, 10 mA
Voltage output
E5CZ
E5CZ-U
Output voltage 12 VDC
±
15% (PNP), max. load current
21 mA, with short-circuit protection circuit
E5AZ
E5EZ
Output voltage 12 VDC +15%/
−
20% (PNP), max. load cur-
rent 40 mA, with short-circuit protection circuit
Current output
4 to 20 mA DC, 0 to 20 mA DC, Load: 600
Ω
max., Resolution: approx.
2,700
Alarm output
E5CZ
E5CZ-U
SPST-NO, 250 VAC, 1 A (resistive load), electrical durability: 100,000
operations
Min. applicable load: 5 V, 10 mA
E5AZ
E5EZ
SPST-NO, 250 VAC, 2 A (resistive load), electrical durability: 100,000
operations
Min. applicable load: 5 V, 10 mA
Control method
2-PID or ON/OFF control
Setting method
Digital setting using front panel keys
Indication method
11-segment/7-segment digital display and single-lighting indicator
Other functions
Depend on the model
Ambient temperature
−
10 to 55
°
C (with no condensation or icing)
Ambient humidity
25% to 85%
Storage temperature
−
25 to 65
°
C (with no condensation or icing)
Altitude
2,000 m or less
Recommended fuse
T2A, 250 VAC, time lag, low shut-off capacity
Installation environment
Installation Category II, Pollution Class 2 (IEC 61010-1 compliant)
Содержание E5AZ
Страница 2: ...E5CZ E5CZ U E5AZ E5EZ Digital Temperature Controller User s Manual Produced September 2008 ...
Страница 3: ...iv ...
Страница 23: ...xxiv ...
Страница 53: ...30 Using the Support Software Port Section 2 3 ...
Страница 79: ...56 Using HB and HS Alarms Section 3 10 ...
Страница 115: ...92 Output Adjustment Functions Section 4 14 ...
Страница 173: ...150 Communications Setting Level Section 5 8 ...
Страница 205: ...182 Index precautions 22 terminal arrangement 21 terminals 21 ...