45850101TH Rev.1
4-48
Oki Data CONFIDENTIAL
4. REPLACEMENT OF PARTS
4.2.25 Low-voltage power supply Assy.
Electric shock hazard.
Be sure to unplug the AC cable as some circuits keep working while the power
cable is connected even after the power is turned off.
When replacing the low-voltage power supply, due to potential electric shock, wear
insulated gloves or be careful not to touch the conductors or terminals of the power
supply directly.
After the AC cord is unplugged, the capacitor may take about one minute to
discharge completely, or could not discharge due to PCB breakdown. Use caution
about electric shock.
②
①
①
(3) Disconnect the two cables
③
.
③
(1) Detach the rear cover Assy. (Refer to section 4.2.5)
(2) Remove the two screws (silver)
①
and detach the cover POW
②
.