2. TROUBLESHOOTING PROCEDURES
2.5.2 Inspection List
Panel display
Cause
Check details
Result
Solution
Inspection is
required.
001:Error
Machine Check
Exception
hardware fault
detection
(board failure
or poor power
supply)
Does this error message
reappear?
Yes
Cycle the power.
Replace the CU/PU board.
Power OFF/ON
002:Error
xxxxxxxx
xxxxxxxx xxxxxxx
003:Error
xxxxxxxx
xxxxxxxx xxxxxxx
004:Error
xxxxxxxx
xxxxxxxx xxxxxxx
005:Error
xxxxxxxx
xxxxxxxx xxxxxxx
006:Error
xxxxxxxx
xxxxxxxx xxxxxxx
007:Error
xxxxxxxx
xxxxxxxx xxxxxxx
Program detects
the wrong
process
Does this error message
reappear?
Yes
Record the eight figures on
the LCD, and cycle the power.
Replace the CU/PU board.
Power OFF/ON
009:Error
Power OFF/ON
010:Error
Power OFF/ON
011:Error
Program detects
the wrong
process
Record the eight figures on
the LCD, and cycle the power.
Power OFF/ON
012:Error
A watchdog
timeout occurs
due to no system
timer interrupt
for unknown
reasons.
Does this error message
reappear?
Yes
Cycle the power.
Replace the CU/ PU board.
Power OFF/ON
024:Error
CU Program
detects the error
for hash on the
DIMM slot
Inspection is
required.
030:Error
Detect the CU
RAM Check
error
Does this error message
reappear?
Yes
Re-implement the RAM DIMM
and turn on the MFP.
Replace the CU/ PU board.
Panel display
Cause
Check details
Result
Solution
Inspection is
required.
040:Error
Detect the CU
EEPROM error
Does this error message
reappear?
Yes
Cycle the power.
Replace the CU/ PU board.
Inspection is
required.
042:Error
Failed to access
to the Flash
ROM that is
directly mounted
on the CU/PU
board
Does this error message
reappear?
Yes
Cycle the power and format
the Flash memory.
Replace the CU/ PU board.
Inspection is
required.
043:Error
The format
varsion of the
Flash differs
from program
supports
Inspection is
required.
045:Error
Failed to fomat
the Flash
memory
Inspection is
required.
049:Error
Incompatibility
between the CU
and the engine
head type
(resolution)
Replace with a head of proper
resolution.
Inspection is
required.
051:Error
Stopped
or unusual
movement the
CU cooling FAN
Replace the CU cooling FAN.
Power OFF/ON
052:Error
A DMA Abort
error was
detected with
the Image
Processor.
Does this error message
reappear?
Yes
Cycle the power.
Replace the DIMM.
Power OFF/ON
054:Error xxx yyy
zzz
Detect the
communication
error between
the Controller
unit and scanner
unit
Record the figures on the
LCD, and close the error
display.
Power OFF/ON
055:Error
Controller unit
cannot detect
the scanner unit
Does this error message
reappear?
Does this error message
reappear?
Yes
Yes
Record the figures on the
LCD, and close the error
display and cycle the power.
Check the connection
between the scanner and
printer.