Oki Data CONFIDENTIAL
45850101TH Rev.1
2-27
2. TROUBLESHOOTING PROCEDURES
No. Category PJL Status
Code
Panel messages
Description
126 Error
350
351
352
353
+
Information
-
Use genuine
%COMPANY_
NAME%
consumables for
max performance.
This should be appeared after the
drum life error messages when
OKIORIGINALCONSUMABLEDISPLAY is ON to
display this.
127 Error
560
561
562
563
+
Information
-
Use genuine
%COMPANY_
NAME%
consumables for
max performance.
This should be appeared after the
drum life error messages when
OKIORIGINALCONSUMABLEDISPLAY is ON to
display this.
128 Error
709
40580
Caution, unknown
Consumable
detected
Go to User Manual
"Trouble Shooting"
to restore operation
Unknown Consumable detected. Use a special
startup(Press Cancel when power on) to start the
printer to on-line, but a history will be recorded.
129 Error
(ONLINE)
519
40364
Receiving data
timeout.
When receiving data by Port9100, LPR, FTP, IPP,
WSD, or Email, a timeout occurred in stream.
130 Error
690
691
692
693
40486(Y)
40487(M)
40488(C)
40485(K)
Incompatible
%COLOR% Image
Drum.
Press the [Details]
button for help.
The signature ID of image drum is not proper
to the distribution channel, but the group of
signature ID is proper.
As probable missing to measure the amount of
drum, the printer notifies error status and stop
printing.
Error 690 : Y
Error 691 : M
Error 692 : C
Error 693 : K
When this error occurs in more than one color
drums, the all drums that have this error status
and a high most priolity error code are displayed.
(Example)
When this error occurs in all drums: YMCK Drum
Regional Mismatch: 690
When this error occurs in MC drums: MC Drum
Regional Mismatch: 691
No. Category PJL Status
Code
Panel messages
Description
131 Error
700
701
702
703
40492(Y)
40493(M)
40494(C)
40491(K)
Incompatible
%COLOR% Image
Drum.
Press the [Details]
button for help.
The signature ID of image drum is not proper
to the distribution channel, and the group of
signature ID is not proper.
Error 700 : Y
Error 701 : M
Error 702 : C
Error 703 : K
When this error occurs in more than one color
drums, the all drums that have this error status
and a high most priolity error code are displayed.
(Example)
When this error occurs in all drums: YMCK Drum
Regional Mismatch: 700
When this error occurs in MC drums: MC Drum
Regional Mismatch: 701
132 Error
704
705
706
707
40496(Y)
40497(M)
40498(C)
40495(K)
Incompatible
%COLOR% Image
Drum.
Please see HELP
for details
The signature ID of image drum is not proper
to the distribution channel, and the group of
signature ID is protected.
Error 704 : Y
Error 705 : M
Error 706 : C
Error 707 : K
When this error occurs in more than one color
drums, the all drums that have this error status
and a high most priolity error code are displayed.
(Example)
When this error occurs in all drums: YMCK Drum
Regional Mismatch: 704
When this error occurs in MC drums: MC Drum