Oki Data CONFIDENTIAL
45850101TH Rev.1
2-30
2. TROUBLESHOOTING PROCEDURES
Panel display
Cause
Check details
Result
Solution
Inspection is
required.
056:Error
Controller unit
cannot detect
the hard disk
Power off the MFP and attach
the hard disk and power on
the MFP.
Power OFF/ON
057:Error
Detect the time
out between the
Controller unit
and scanner unit
01 : No ACK for
read beginning
command
02 : No ACK
for read cancel
command
03 : No ACK
for SIP cancel
command
Record the figures on the
lower right side of the LCD,
and cycle the power.
Power OFF/ON
058:Error
Detect the error
at scanner
control section
01 : SIP internal
error
02 : S
ca
n
Model internal
error
03 : SPB internal
error
Record the figures on the
lower right side of the LCD,
and cycle the power.
Power OFF/ON
059:Error
Detect the
communication
error between
the Controller
unit and scanner
unit
Record the figures on the
LCD, and close the error
display.
Inspection is
required.
067:Error
Detect the
communication
error with the
Sleep Mode
interface
supervisor
program.
Does this error recur?
Yes
Cycle the power.
Replace the CU/PU board.
Inspection is
required.
069:Error
Malfunction of
the NIC chip was
detected.
Does this error recur?
Yes
Cycle the power.
Replace the CU/PU board.
Power OFF/ON
070:Error
A PSE firmware
error was
detected.
If display the address on the
LCD, record the figures and
close the error display and
cycle the power.
Panel display
Cause
Check details
Result
Solution
Power OFF/ON
072:Error
I/F error between
CU and PU
Record the figures on the
lower right side of the LCD,
and cycle the power.
Power OFF/ON
073:Error c/
xxxxxxxx
Detect the Video
circuit over run.
Record the figures on the
lower right side of the LCD,
and cycle the power.
Power OFF/ON
075:Error c/
xxxxxxxx
Video error.
An error was
detected in
expanding image
data.
Power OFF/ON
077:Error
VIC Illegal
Decomp Error
Does this error recur?
Yes
Cycle the power.
Replace the CU/PU board.
Inspection is
required.
078:Error
Communication
Error with
Operator Panel
Unit
Does this error recur?
Yes
Cycle the power.
Replace the CU/PU board.
Power OFF/ON
080:Error
Failed to access
to the parameter
storage
Does this error recur?
Yes
Cycle the power.
Replace the CU/PU board.
Inspection is
required.
081:Error
Parameter
matching check
error
Format the EEPROM , Flash
and need the initialize.
Inspection is
required.
090:Error
Detect the error
at stapler unit.
Replace the stapler unit or
CU/PU Board,and cycle the
power.
Inspection is
required.
104:Error
An engine
EEPROM read/
write error was
detected at
power on
Inspection is
required.
105:Error
Not detect the
EEPROM at
power on
Inspection is
required.
106:Error
Detect the error
at engine control
logic
Cycle the power.
Inspection is
required.
111:Error
A duplex unit for
another model
was detected
Is a duplex unit provided
for this model installed?
No
Install a correct duplex unit.
Inspection is
required.
112:Error
A Tray2 for
another model
was detected.
Is a Tray2 provided for
this model installed?
No
Install a correct Tray2.
Inspection is
required.
113:Error
A Tray3 for
another model
was detected.
Is a Tray3 provided for
this model installed?
No
Install a correct Tray3.