Q-Code User Manual
Ver. 7.0 2021/11/30
57
NY4 / NY5
NX1
Time Base:
The base timing of Action (default is
1ms).
Frame Rate:
The refresh rate of Action signals
(default is 80)
Timer:
The source of the Action counter. Timer0 /
Timer1 / Timer2 / PWMA / PWMB as the
timer is more accurate, but Timer0/1/2 must not be shared with the playback of sound. For
example, if Timer0 is selected as Action Timer, Ch0 cannot be used to play the sound,
Ex.
Action_FrameRate
= 80
Action_TimeBase
= 1ms
Action_Timer
= Timer1
Note: The higher Frame Rate, the larger Data ROM Size consumption. The lower refresh rate,
the more glitter LED will display.
3.9.1.15 Random
Random means the range of randomly generated numbers. (Default
value is Disable)
For NY4 / NY5 / NY5+ / NY6 / NY7 / NY9T, the value of the randomly
generated number can be from 0 to 255.
For NX1, the value of the randomly generated number can be from 0 to
65535.
Ex.
Random
= 122
3.9.1.16 Debounce
Power On Trigger
When user holds the button and power on, system will execute
the key path immediately after “PowerOn” path is done (Default
value is Enable).
NY5+ / NY6 / NY7 / NX1 series allows user enabling / disabling
Power On Trigger function of Direct Key and Matrix Key
separately via Direct_PowerOnTrigger and
Matrix_PowerOnTrigger option. NY4 / NY5 / NY9T series
cannot switch Power On Trigger function separately, only
support the PowerOnTrigger option.
Note: