Q-Code User Manual
Ver. 7.0 2021/11/30
85
The trigger number must be identical to the number of input pins, and the triggered events must be
separated by TAB or Space.
The status of the input pin can be in one of the following forms:
Format
Trigger
Description
X
Ignore
No action.
Path1
Falling edge Execute Path1 as input pin changed from high to low electric potential.
/Path2
Rising edge Execute Path2 as input pin changed from low to high electric potential.
Path1/Path2
Falling edge &
Rising edge
Execute Path1 as input pin changed from high to low electric potential.
Execute Path2 as input pin changed from low to high electric potential.
Ex.
[Input State]
Input_0:
TR1R
X
/TR3F
TR4R/TR4F
Operating steps: Input State
→
Input State
→
Add State Name
→
Add PathName
→
OK, and the
actual operating steps are shown below.
Click Input State and the following dialog box will appear.