although needs to add a NY8A051D, the tag can be made as PCB antenna. After setting
project, An additional CarrierGen-530KHz.bin for programming to NY8A051D will be
automatically generated by
Q-Code
.
Slow Pin:
The rest time of Slow Mode is counted by RC charging / discharging of specified I/O. To
enable Slow Mode, it is necessary to connect a 100K
Ω
resistor and 0.1uF capacitor in
parallel to the specified I/O.
Scan Interval:
QFID Slow Mode will scan for tags once and rest several times, the rest times is
determined by the value of Scan Interval. For example, when Scan Interval is selected
as 2, it means to scan once and rest twice. If the scan time is 200ms, the rest time is
about 400ms. The scan time is determined by tag number. The user can also change
the resistance and capacitance to adjust the Interval unit time. The calculated unit time
after the change is as follows.
Interval
(new)
= (Interval
(original)
x R x C) / 0.01
Note: The rest time is an approximate value and may deviate
.
QFID_GroupX_Mode:
QFID mode. ID is for identifying Tag only. ID+Input is to identify Tag and read
the I/O state on Tag.
QFID_GroupX_Tags:
The available numbers of tag. 1 to 16 tags are applicable if
QFID_GroupX_Mode is ID, and the corresponding tag IDs are Tag0 ~ Tag15. 1
to 8 tags are applicable if QFID_GroupX_Mode is ID+input, and the
corresponding tag IDs are Tag0 ~ Tag7.
QFID_VID:
Set the Vender ID of product, the range is 0x0~0x1FF. If the Vender ID of Tag is different
from the reader’s setting, the Tag won’t be recognized.
QFID_PID:
Set the Project ID of product, the range is 0x0~0x3FF. If the Project ID of Tag is different
from the reader’s setting, the Tag won’t be recognized.
QFID_VID / QFID_PID is used to avoid the interference between different products’ Tags. The VID /
PID of Tag and reader must be exactly the same in order to be recognized. User can also disable the
VID / PID function.
Note:
1. NX1 does not support Slow Pin and Scankey Interval options.
2. NY7 only supports QFID_Group0.
User has to define the corresponding trigger state in
[QFID]
section. The entry in QFID state specifies
the action to perform when Tag is detected by reader or left reader. The entry number cannot exceed
the number of QFID_GroupX_Tags, and the entries have to be separated by blank (TAB or Space).
The allowed entries are as follows.
Fomat
Tag Trigger Type
Descriptions
X
Ignore
No action.
Path1
Detect
When Tag is detected by reader, executing Path1.