Q-Code User Manual
Ver. 7.0 2021/11/30
56
NX1
NY4 / NY5 / NY5+ /
NY6 / NY7 / NY9
3.9.1.14 Action
Frame Rate:
The refresh rate of Action signals (default is 80).
Compression:
Action compression function (default is Enable).
Timer:
The source of the Action counter. Timer0 / Timer1 / Timer2 / PWMA / PWMB as the timer is
more accurate, but Timer0/1/2 must not be shared with the playback of sound. For example, if
Timer0 is selected as Action Timer, Ch0 cannot be used to play the sound,
Ex.
ActionCompression
= Enable
Ex.
Action_FrameRate
= 80
Ex.
Action_Timer
= Timer1
Note:
1. NY4 / NY5 / NY5+ / NY6 / NY7 / NY9T do not support Timer option.
2. NX1 does not support the Action Compresss option.
3. The higher Frame Rate, the larger Data ROM Size consumption.
4. The lower refresh rate, the more glitter LED will display.
5.
In NY9T, the resolution of Action counter is only 1ms, the variable range is narrow, and it
is not recommended that set Ascend/Descend as output signals.
NY4 / NY5 / NY5+ / NY6 / NY7 / NY9T
Frame Rate:
The refresh rate of Action signals (default is 80).
Compression:
Action compression function (default is Enable).
Ex.
ActionCompression
= Enable
Action_FrameRate
= 80
Note:
1. The higher Frame Rate, the larger Data ROM Size consumption. The lower refresh rate,
the more glitter LED will display.
2. In NY9T, the resolution of Action counter is only 1ms, the variable range is narrow, and
it is not recommended that set Ascend/Descend as output signals.