Configuring SNMP settings for Device Manager access
99
Variable
Value
NextHop
Configures the IP address of the next
hop of this route. In the case of a
route bound to an interface realized
through a broadcast media, the value
of this box is the agent IP address on
that interface.
NextHopVrfId
Indicates the next hop VRF ID in
interVRF static-route configuration.
Enable
Initializes the static route.
Metric
Configures the primary routing metric
for this route.
Preference
Indicates the route preference of
this entry. If you can use more than
one route to forward IP traffic, the
switch uses the route with the highest
preference. The higher the number,
the higher the preference.
LocalNextHop
If you select this variable, this box
indicates the static route is active
only if you configure the switch with
a local route to the network. If you
do not select this variable, this box
indicates the static route is active if
you configure the switch with a local
route or dynamic route.
Configuring SNMP settings for Device Manager access
Use this procedure to configure important communication parameters such
as the polling interval, timeout, and retry count. You can configure these
parameters before or after you open a device.
Device Manager automatically determines the software version of the
device you select.
Procedure steps
Step
Action
1
From the initial Device Manager window menu bar, select
Device, Properties, Devices.
A list of IP addresses for configured devices appears.
2
Select the IP address for the device you want to edit.
3
Click Edit.
The Device Manager Properties dialog box appears.
Nortel Ethernet Routing Switch 8600
Commissioning
NN46205-319
01.01
Standard
30 May 2008
Copyright © 2008 Nortel Networks
.