Remote connection configuration using Device Manager
4
Select the properties you want to change and configure their
values.
5
Click OK.
--End--
Variable definitions
Use the data in the following table to configure the Properties dialog box.
Variable
Value
Status Interval
Interval you use to gather statistics
and status information (default is 20
seconds).
(IfTraps, Status Interval)
The interval, in seconds, you use
to gather statistics and status
information. Configure this value if you
select the Register for Traps box.
Hotswap Detect every
The number of intervals at which
Device Manager checks for module
hot swaps.
Enable
If you select this variable, Device
Manager polls the switch according
to the settings you select prior to the
Enable box.
Retry Count
If Device Manager cannot transmit
polling information at start up, the
number of times Device Manager
retransmits polling information.
Timeout
Length of the retry for each polling
waiting period. If you access the
device through a slow link, you can
increase the timeout interval and
change the retransmission strategy to
superlinear.
Trace
If you select this variable, you can
perform trace routes.
Register for Traps
If you select this variable, Device
Manager registers a trap.
Listen for Traps
If you select this variable, Device
Manager monitors for a trap.
Max Traps in Log
The specified number of traps that
can exist in the trap log. The default is
500.
Nortel Ethernet Routing Switch 8600
Commissioning
NN46205-319
01.01
Standard
30 May 2008
Copyright © 2008 Nortel Networks
.