2
1
Repair
7-19
P/N 7105144G
2008 Nordson Corporation
VersaBlue_NW
Installing Service Kit
Each kit contains two O-rings and high-temperature grease.
NOTE:
Screw in/out only when the safety valve (2, Fig. 7-29) and pump are
warm and the material is soft (approx. 70
°
C / 158
°
F, depending on
material).
Service kit P/N: 394592 (for safety valve and safety valve with Reed switch)
Required tools:
Open-jawed wrench: size 19 for standard safety valve; size 24 safety valve with Reed switch
Pliers
Torque wrench
1.
Close the tank isolation valve (1, Fig. 7-29).
2.
When present: Unscrew the connecting cable from the Reed switch.
3.
Use an open-jawed wrench to screw out the safety valve, then extract with
a pliers.
4.
Remove outer O-rings and clean outside of safety valve.
5.
Install new O-rings.
6.
Apply grease to all threads and O-rings.
7.
To prevent damage to the O-rings, carefully guide the valve into the hole
when the melter is warm.
8.
Tighten valve with a torque wrench.
Torque: 15 Nm (133 lbin)
9.
When present: Screw the connecting cable back onto the Reed switch.
10. Open tank isolation valve.
Содержание VersaBlue VB Series
Страница 40: ...Introduction 2 14 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Страница 66: ...Installation 3 26 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Страница 150: ...Operation 4 84 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Страница 174: ...Maintenance 5 24 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Страница 236: ...Parts 8 2 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Страница 250: ...Options 10 6 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Страница 254: ...Password A 4 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Страница 280: ...Glossary D 16 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...