1
Maintenance
5-18
P/N 7105144G
2008 Nordson Corporation
VersaBlue_NW
Tank Isolation Valve
Installing Service Kit
Each kit contains one O-ring and high-temperature grease.
Service Kit, for P/N refer to separate
Parts List
.
Required tools:
Allan key, size 4
Pliers
Open-jawed wrench, size 13, to operate the tank isolation valve
Size 13
1.
Heat melter to operating temperature.
WARNING:
Hot! Risk of burns. Wear appropriate protective
clothing/equipment.
2.
Empty tank.
3.
Release four Allan screws M5 and lift off plate. Use a pliers to extract the
tank isolation valve from the safety valve plate.
4.
Remove old O-ring and clean tank isolation valve.
5.
Apply high temperature grease to O-ring, then install again with tank
isolation valve.
1
0
0: Closed
Tank side
Pump side
1: Open
NOTE:
Operate the tank isolation valve only when the melter has reached
operating temperature.