Automatic enter standby
after motor stop
60
min
Not
enabled
60
min Enabled
Manual standby duration
Operation
4-47
P/N 7105144G
2008 Nordson Corporation
VersaBlue_NW
Standby
Standby serves to protect the hot melt material and to save energy during
breaks in production.
For information on setting the temperature standby value (value by which
the setpoint temperature is reduced), refer to
Control Panel
−
Overview
−
/
T2.
Automatic Entry
Standby is entered as soon as all of the motors have been stopped for a
certain time. Enable
Automatic enter standby
for this purpose.
Manual Exit
Automatic standby is exited by the operator on the control panel
.
Manual standby duration
is ineffective here.
V9
Automatic enter standby after motor stop:
Not enabled
(or 60 min if enabled)
Manual Entry/Exit (Control Panel)
External Entry/Exit (Interface)
Either the operator enters and exits standby on the control panel key
or this occurs via the interface
Standard I/O
.
Automatic Exit
Exit standby can also occur automatically. Enable
Manual standby
duration
for this purpose. After the set time has expired, the melter automatically
returns to heatup guided by reference channel.
Manual standby duration:
Not enabled
(or 60 min if enabled)
Entering/Exiting via the Seven-day Clock
Refer to
Control Panel
−
Overview
−
/ V7
and
V8
.
Содержание VersaBlue VB Series
Страница 40: ...Introduction 2 14 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Страница 66: ...Installation 3 26 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Страница 150: ...Operation 4 84 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Страница 174: ...Maintenance 5 24 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Страница 236: ...Parts 8 2 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Страница 250: ...Options 10 6 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Страница 254: ...Password A 4 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Страница 280: ...Glossary D 16 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...