1
I/O
Repair
7-22
P/N 7105144G
2008 Nordson Corporation
VersaBlue_NW
Replacing I/O Board, Temperature Control Board
NOTE:
Switch / DIP switch settings, bus terminating resistors yes/no and
jumper settings are to be assumed from the replaced board.
The CAN address is set on the dials using a screwdriver.
I/O Board
Setting CAN Address
Dial (default)
Board no.
SW1
SW2
0
5
1
0
6
2
NOTE:
Dial setting SW1 may not be changed.
Temperature Control Board
Setting CAN Address
Dial (default)
Board no.
Temperature channel
S1
S2
7
1
1
1 to 6
7
2
2
7 to 12
7
3
3
13 to 18
NOTE:
The switch setting S1 may not be changed.