Troubleshooting
6-14
P/N 7105144G
2008 Nordson Corporation
VersaBlue_NW
Troubleshooting Tables
Melter not Functioning
Problem
Possible Cause
Corrective Action
No line voltage
−
Connect line voltage
Main switch not switched
on
−
Switch on main switch
Main switch defective
−
Replace main switch
Main circuit breaker
activated
−
Switch on main circuit breaker
Main circuit breaker
activated again
Check for short circuit in melter or
accessories
−
24 V
DC
power supply
defective
−
Replace
IP address was assigned
twice in the network
Check the IP addresses and set a
unique IP address for each node
One Channel does not Heat
Problem
Possible Cause
Corrective Action
Channel is deactived
−
Activate the temperature channel on
the control panel (or via the optional
field bus)
The channel is assigned
to a group, and the group
is deactived or in
standby
Check the state of the group in the
screen
Switch application group(s)
(Refer to section
Operation
)
Activate the group via the control
panel, or if set up so, via the
Standard I/O interface.
Channel is in display
mode
−
Switch to control mode
Содержание VersaBlue VB Series
Страница 40: ...Introduction 2 14 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Страница 66: ...Installation 3 26 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Страница 150: ...Operation 4 84 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Страница 174: ...Maintenance 5 24 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Страница 236: ...Parts 8 2 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Страница 250: ...Options 10 6 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Страница 254: ...Password A 4 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Страница 280: ...Glossary D 16 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...