Troubleshooting
6-26
P/N 7105144G
2008 Nordson Corporation
VersaBlue_NW
LEDs of Temperature Control Board
D13
D14
D8
D6
D2
D5
D4
D3
D1
D7
LED
Meaning
D7
Operating voltage present
D8
CAN data received or transmitted
D14
No connection to control unit (IPC)
D13
Lit: Controller software reset
Flashing: CAN fault counter overflow, stack error, power
down not finished properly
D1
Heater output of the first channel is switched on.
D2 (... D6)
Heater output of the second (... sixth) channel is switched
on.