Max. in key-to-line
mode
10.0
Pump 1
0.0
V
V
Act
ual
ON
Coupling broken
monitoring
PID pressure
control parameters
Pressure
sensor B
Control mode
Pressure alarm monitoring
(global)
OFF
Pressure
sensor A
Pressure
sensor C
Operation
4-67
P/N 7105144G
2008 Nordson Corporation
VersaBlue_NW
Threshold Switch
NOTE:
The threshold switch is automatically deactivated as long as
pressure build-up is enabled.
In threshold switch mode the motors are started and stopped by the line
speed signal.
Motor
100 %
Start at:
Stop at:
0
Off
On
(lower threshold
value)
(upper threshold
value)
Line speed
signal
value
When the upper threshold value is exceeded, the motor starts; when the
value falls below the lower value, the motor stops.
Start at:
10.0 %
Stop at:
5.0 %
If there are
no
sensors present, touching the
key leads to a screen in
which the coupling broken monitor can be switched on or off.
M2.2
Screen 4: Pressure Alarms, Speed / Pressure Control
If pressure sensors are present, touching the
key leads to the fourth
parameter screen.
Pressure alarm monitoring (global)
Global = for all motors
Pressure alarm monitoring is available only with options
Pressure display
and
Pressure control.
M5
If pressure alarm monitoring is switched on, underpressure and
overpressure are monitored. Alarms are triggered depending on the set
warning and fault values (Refer to
Pressure Sensor A
).
NOTE:
When the speed is regulated in key-to-line mode, an underpressure
warning can be displayed during parent machine startup until the melter
speed setpoint is reached.
Содержание VersaBlue VB Series
Страница 40: ...Introduction 2 14 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Страница 66: ...Installation 3 26 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Страница 150: ...Operation 4 84 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Страница 174: ...Maintenance 5 24 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Страница 236: ...Parts 8 2 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Страница 250: ...Options 10 6 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Страница 254: ...Password A 4 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Страница 280: ...Glossary D 16 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...