0
40
60
80
100
20
100.0
0.0
20 40 60 80 100 [%]
80.0
rpm
Line speed for max. pump speed
Max.
pump
speed
Min.
pump
speed
rpm
rpm
0
Actual
Line speed for min. pump speed
0.0
%
Operation
4-65
P/N 7105144G
2008 Nordson Corporation
VersaBlue_NW
Screen 2: Key-to-line
Touch the
key to move to the second setup screen.
NOTE:
The graph does not change to adapt to the entered values.
M3
Min. pump speed:
Pump speed setpoint when the external line speed
signal lies below the entered value Line speed for min. pump speed.
0.0 min
-1
Max. pump speed:
Pump speed setpoint when the external line speed
signal exceeds the entered value Line speed for max. pump speed.
80.0 min
-1
Line speed for min./max. pump speed:
Line speed signal value in %,
below or above which the pumps begin to rotate at the set min./max. speed.
Max: 100.0 %
Min: 0.0 %
To M2.2. This key is available only with separate line speed signal
inputs (option).
Содержание VersaBlue VB Series
Страница 40: ...Introduction 2 14 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Страница 66: ...Installation 3 26 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Страница 150: ...Operation 4 84 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Страница 174: ...Maintenance 5 24 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Страница 236: ...Parts 8 2 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Страница 250: ...Options 10 6 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Страница 254: ...Password A 4 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Страница 280: ...Glossary D 16 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...