1
2
rpm
Pump 1
rpm
Pump 2
Key-to-line
Key-to-line
bar
bar
Flow control mode
(for all pumps)
Pump 1
Pump speed
5.0 rpm
En-
abled
Operation
4-75
P/N 7105144G
2008 Nordson Corporation
VersaBlue_NW
Variation 1:
Line stop signal
Enable pressure build-up feature and select condition for which the
pressure build-up is to be started (here:
Line stop signal
).
The motors are speed-controlled during production. If the signal
Line stop
is
switched via the interface
Standard I/O
or the field bus, the motors are
pressure-controlled to the value
Setpoint for pressure build-up
.
As soon as the signal
Line started
is switched, the melter returns to
speed-controlled mode.