4. Select assignment!
Replacing motor controller
1. Switch off main contactor
and wait 3 min!
Replacing motor controller
New MC
Main
contactor
Repair
7-7
P/N 7105144G
2008 Nordson Corporation
VersaBlue_NW
5. In this case: Touch key PUMP 2.
Exit the screen again by touching the door symbol.
6. Switch off the main contactor and wait 3 min.
7. Disconnect the operating voltage from MC 1, 2 and 3. Connect MC 4.
8. Switch on main contactor.
9. Select assignment. Touch key PUMP 4.
10. Switch off the main contactor and wait 3 min.
11. Reattach all motor controller connections. In this case: MC 1, 2 and 3.
12. Switch on main contactor.
All motor controllers are now assigned.
13. Exit the screen again by touching the door symbol.
NOTE:
The screen can not be exited until all of the motor controllers
have been assigned.
14. Switch melter off and on again with main switch.
Содержание VersaBlue VB Series
Страница 40: ...Introduction 2 14 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Страница 66: ...Installation 3 26 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Страница 150: ...Operation 4 84 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Страница 174: ...Maintenance 5 24 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Страница 236: ...Parts 8 2 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Страница 250: ...Options 10 6 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Страница 254: ...Password A 4 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...
Страница 280: ...Glossary D 16 P N 7105144G 2008 Nordson Corporation VersaBlue_NW...